Method for rapid separation of immunoglobulin M from immunoglobulin G antibodies by using reorienting gardients in vertical rotors

Wolf, Hans J. and Frösner, G. G. and Deinhardt, F. (1979) Method for rapid separation of immunoglobulin M from immunoglobulin G antibodies by using reorienting gardients in vertical rotors. Journal of clinical microbiology 9 (4), pp. 544-546.

[img]
Preview
PDF
Download (386kB)

at PubMed


Abstract

The parameters for the use of reorienting gradients in vertical rotors for rapid separation of immunoglobulin M from immunoglobulin G on a preparative scale for the rapid diagnosis of infectious diseases are described.


Export bibliographical data



Item type:Article
Date:1979
Institutions:Medicine > Lehrstuhl für Medizinische Mikrobiologie und Hygiene
Identification Number:
ValueType
6034985PubMed ID
Classification:
NotationType
Centrifugation, Density Gradient/methodsMESH
Communicable Diseases/diagnosisMESH
Diagnosis, DifferentialMESH
HumansMESH
Immunoglobulin G/isolation & purificationMESH
Immunoglobulin M/isolation & purificationMESH
RadioimmunoassayMESH