Startseite UB

Method for rapid separation of immunoglobulin M from immunoglobulin G antibodies by using reorienting gardients in vertical rotors

Wolf, Hans J. and Frösner, G. G. and Deinhardt, F. (1979) Method for rapid separation of immunoglobulin M from immunoglobulin G antibodies by using reorienting gardients in vertical rotors. Journal of clinical microbiology 9 (4), pp. 544-546.

[img]
Preview
PDF
Download (386kB)

at PubMed


Abstract

The parameters for the use of reorienting gradients in vertical rotors for rapid separation of immunoglobulin M from immunoglobulin G on a preparative scale for the rapid diagnosis of infectious diseases are ...

plus


Export bibliographical data



Item Type:Article
Date:1979
Institutions:Medicine > Lehrstuhl für Medizinische Mikrobiologie und Hygiene
Identification Number:
ValueType
6034985PubMed ID
Classification:
NotationType
Centrifugation, Density Gradient/methodsMESH
Communicable Diseases/diagnosisMESH
Diagnosis, DifferentialMESH
HumansMESH
Immunoglobulin G/isolation & purificationMESH
Immunoglobulin M/isolation & purificationMESH
RadioimmunoassayMESH
Subjects:600 Technology > 610 Medical sciences Medicine
Status:Published
Refereed:Unknown
Created at the University of Regensburg:Unknown
Owner: Universitätsbibliothek Regensburg
Deposited On:01 Apr 2011 11:34
Last Modified:13 Mar 2014 17:09
Item ID:20350
Owner Only: item control page

Downloads

Downloads per month over past year

  1. University

University Library

Publication Server

Contact person
Gernot Deinzer

Telefon 0941 943-2759
Contact