Direkt zum Inhalt

Steiner, Mark-Steven ; Meier, Robert J. ; Dürkop, Axel ; Wolfbeis, Otto S.

Chromogenic Sensing of Biogenic Amines Using a Chameleon Probe and the Red−Green−Blue Readout of Digital Camera Images

Steiner, Mark-Steven, Meier, Robert J., Dürkop, Axel und Wolfbeis, Otto S. (2010) Chromogenic Sensing of Biogenic Amines Using a Chameleon Probe and the Red−Green−Blue Readout of Digital Camera Images. Analytical chemistry 82 (20), S. 8402-8405.

Veröffentlichungsdatum dieses Volltextes: 18 Mrz 2011 06:40
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.19952


Zusammenfassung

We report on sensing spots containing an amine reactive chromogenic probe and a green fluorescent (amine insensitive) reference dye incorporated in a hydrogel matrix on a solid support. Such spots enable rapid and direct determination of primary amines and, especially, biogenic amines (BA). A distinct color change from blue to red occurs on dipping the test spots into a pH 9.0 sample containing ...

We report on sensing spots containing an amine reactive chromogenic probe and a green fluorescent (amine insensitive) reference dye incorporated in a hydrogel matrix on a solid support. Such spots enable rapid and direct determination of primary amines and, especially, biogenic amines (BA). A distinct color change from blue to red occurs on dipping the test spots into a pH 9.0 sample containing primary amines. BAs can be determined in the concentration range from 0.01 to 10 mM within 15 min, enabling rapid, qualitative, and semiquantitative evaluation. In the "photographic" approach, the typically 4-7.5-fold increase in fluorescence intensity of the probe at 620 nm along with the constant green fluorescence at 515 nm of a reference dye are used for quantitation of BAs. The sensing spots are photoexcited with high-power 505 nm light-emitting diodes (LEDs) in a black box. A digital picture is acquired with a commercially available digital camera, and the color information is extracted via red-green-blue (RGB) readout. The ratio of the intensities of the red (signal) channel and the green (reference) channel yields pseudocolor pictures and calibration plots.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftAnalytical chemistry
Verlag:AMER CHEMICAL SOC
Ort der Veröffentlichung:WASHINGTON
Band:82
Nummer des Zeitschriftenheftes oder des Kapitels:20
Seitenbereich:S. 8402-8405
Datum17 September 2010
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, ehemals Prof. Wolfbeis)
Identifikationsnummer
WertTyp
10.1021/ac102029jDOI
Stichwörter / KeywordsCOLORIMETRIC SENSOR; DERIVATIZATION; HISTAMINE; FISH; DISCRIMINATION; CHROMATOGRAPHY; POLYAMINES; PROTEINS; LABELS; ARRAY;
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
StatusVeröffentlicht
BegutachtetUnbekannt / Keine Angabe
An der Universität Regensburg entstandenUnbekannt / Keine Angabe
Dokumenten-ID19952

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben