| Download ( PDF | 244kB) Nur für Mitarbeiter des Archivs |
Indicator-Loaded Permeation-Selective Microbeads for Use in Fiber Optic Simultaneous Sensing of pH and Dissolved Oxygen
Vasylevska, Ganna S., Borisov, Sergey M.
, Krause, Christian und Wolfbeis, Otto S.
(2006)
Indicator-Loaded Permeation-Selective Microbeads for Use in Fiber Optic Simultaneous Sensing of pH and Dissolved Oxygen.
Chemistry of Materials 18 (19), S. 4609-4616.
Veröffentlichungsdatum dieses Volltextes: 18 Mrz 2011 08:09
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.20204
Zusammenfassung
New materials are described that lead to sensors capable of simultaneous sensing of pH and oxygen via a single-fiber optic sensor. They make use of a pH probe based on carboxyfluorescein, and of a ruthenium(II) complex acting as a probe for dissolved oxygen. The selectivity of the probes was considerably improved by incorporating them into two kinds of microparticles, each of specific permeation ...
New materials are described that lead to sensors capable of simultaneous sensing of pH and oxygen via a single-fiber optic sensor. They make use of a pH probe based on carboxyfluorescein, and of a ruthenium(II) complex acting as a probe for dissolved oxygen. The selectivity of the probes was considerably improved by incorporating them into two kinds of microparticles, each of specific permeation selectivity. The pH probe was immobilized on particles made from proton permeable amino-modified poly(hydroxyethyl methacrylate), while the oxygen probe was physically immobilized in beads made from an organically modified sol-gel. Both kinds of beads were then dispersed into a hydrogel matrix and placed at the distal end of an optical fiber waveguide for optical interrogation. A phase-modulated blue-green LED serves as the light source for exciting luminescence whose average decay times or phase shifts serve as the analytical information. Data are evaluated by a modified dual luminophore referencing (m-DLR) method which relates the phase shift (as measured at two different frequencies) to pH and to oxygen partial pressure. The dually sensing material performs best if the sensing matrix is very homogeneous and if the microbeads have a diameter of < 3 mu m.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Chemistry of Materials | ||||
| Verlag: | AMER CHEMICAL SOC | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | WASHINGTON | ||||
| Band: | 18 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 19 | ||||
| Seitenbereich: | S. 4609-4616 | ||||
| Datum | 16 August 2006 | ||||
| Institutionen | Chemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, ehemals Prof. Wolfbeis) | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | SILICA FILMS; SENSORS; RUTHENIUM(II); OPTIMIZATION; COMPLEXES; POLYMERS; PLATFORM; CHLORIDE; RANGE; | ||||
| Dewey-Dezimal-Klassifikation | 500 Naturwissenschaften und Mathematik > 540 Chemie | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Unbekannt / Keine Angabe | ||||
| An der Universität Regensburg entstanden | Unbekannt / Keine Angabe | ||||
| Dokumenten-ID | 20204 |
Downloadstatistik
Downloadstatistik