| Download ( PDF | 189kB) Nur für Mitarbeiter des Archivs |
Dual Lifetime Referencing as Applied to a Chloride Optical Sensor
Huber, Christian, Klimant, Ingo, Krause, Christian und Wolfbeis, Otto S.
(2001)
Dual Lifetime Referencing as Applied to a Chloride Optical Sensor.
Analytical Chemistry 73 (9), S. 2097-2103.
Veröffentlichungsdatum dieses Volltextes: 15 Apr 2011 09:18
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.20447
Zusammenfassung
A membrane with an optical response to chloride has been developed that contains two luminophores that display two largely different decay times. The first luminophore (the "reference") is a chloride-insensitive ruthenium metal-ligand complex possessing a decay time in the microsecond range. The second luminophore is the short-lived chloride-quenchable fluorescent probe lucigenin. Both are ...
A membrane with an optical response to chloride has been developed that contains two luminophores that display two largely different decay times. The first luminophore (the "reference") is a chloride-insensitive ruthenium metal-ligand complex possessing a decay time in the microsecond range. The second luminophore is the short-lived chloride-quenchable fluorescent probe lucigenin. Both are contained in a hydrogel matrix and are excited by a blue LED emitting sinusoidally modulated light. Under these conditions, the chloride-dependent fluorescence intensity of lucigenin can be converted in an analyte-dependent fluorescence phase shift that depends on the ratio of the two luminescence intensities and can be measured at modulation frequencies of typically 45 kHz. The dynamic range of this sensor can be adjusted by either varying the ratio of the two luminophores dr selecting a particular optical filter combination.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Analytical Chemistry | ||||
| Verlag: | AMER CHEMICAL SOC | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | WASHINGTON | ||||
| Band: | 73 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 9 | ||||
| Seitenbereich: | S. 2097-2103 | ||||
| Datum | 2001 | ||||
| Institutionen | Chemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, ehemals Prof. Wolfbeis) | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | SOLVENT-POLYMERIC MEMBRANE; COEXTRACTION; COMPLEXES; FILMS; PH; | ||||
| Dewey-Dezimal-Klassifikation | 500 Naturwissenschaften und Mathematik > 540 Chemie | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Unbekannt / Keine Angabe | ||||
| An der Universität Regensburg entstanden | Unbekannt / Keine Angabe | ||||
| Dokumenten-ID | 20447 |
Downloadstatistik
Downloadstatistik