Direkt zum Inhalt

Apostolidis, Athanasios ; Lehmann, Hartmut ; Schwotzer, Günter ; Willsch, Reinhardt ; Prior, Albert ; Wolfgang, Jürgen ; Klimant, Ingo ; Wolfbeis, Otto S.

Fiber optic multi-channel protein detector for use in preparative continuous annular chromatography

Apostolidis, Athanasios, Lehmann, Hartmut, Schwotzer, Günter, Willsch, Reinhardt, Prior, Albert, Wolfgang, Jürgen, Klimant, Ingo und Wolfbeis, Otto S. (2002) Fiber optic multi-channel protein detector for use in preparative continuous annular chromatography. Journal of Chromatography A 967, S. 183-189.

Veröffentlichungsdatum dieses Volltextes: 13 Mai 2011 08:26
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.20764


Zusammenfassung

Continuous annular chromatography is an effective method in the separation of preparative scale quantities of biological compounds including proteins where established batch chromatography borders on it. The need for identification or quantification of proteins triggered the development of respective detection units. Here, we describe two types of optical multi-channel detectors. The first is a ...

Continuous annular chromatography is an effective method in the separation of preparative scale quantities of biological compounds including proteins where established batch chromatography borders on it. The need for identification or quantification of proteins triggered the development of respective detection units. Here, we describe two types of optical multi-channel detectors. The first is a fiber optic multi-channel detector suitable for the separation of aqueous protein solutions. The second is a technically improved (circular optic) device suitable for application in multi-channel detection. Specifically, UV-absorption measurements of proteins at 280 nm were carried out using newly designed fiber optic detectors having eight and 16 channels, Calibration plots were established for a series of stock solutions of known concentrations of proteins, Mathematical functions were derived from these calibration data to simulate the response of the detector. Limits of detection and the ranges of validity of the fit functions were determined. The 16-channel detector has a theoretical limit of detection that is equivalent to absorbance changes of 10(-4) Units. (C) 2002 Elsevier Science B.V. All rights reserved.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftJournal of Chromatography A
Verlag:ELSEVIER SCIENCE BV
Ort der Veröffentlichung:AMSTERDAM
Band:967
Seitenbereich:S. 183-189
Datum2002
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik
Identifikationsnummer
WertTyp
10.1016/S0021-9673(02)00755-0DOI
Stichwörter / KeywordsFLOW-INJECTION ANALYSIS; IN-SITU DETERMINATION; SEA-WATER; SEPARATION; annular chromatography; multi-channel optical detection; fiber optics; detection, LC; preparative chromatography; proteins
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
StatusVeröffentlicht
BegutachtetUnbekannt / Keine Angabe
An der Universität Regensburg entstandenUnbekannt / Keine Angabe
Dokumenten-ID20764

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben