| Download ( PDF | 12MB) | License: Publishing license for publications excluding print on demand |
Biomechanische Analyse eines bionischen Plattendesigns zur Versorgung von Kalkaneusfrakturen
Kerschbaum, Maximilian (2014) Biomechanische Analyse eines bionischen Plattendesigns zur Versorgung von Kalkaneusfrakturen. PhD, Universität Regensburg.Date of publication of this fulltext: 03 Jun 2014 13:34
Thesis of the University of Regensburg
DOI to cite this document: 10.5283/epub.30061
Abstract (German)
In der vorliegenden Arbeit wurde ein neuartiger Versuchsaufbau zur biomechanischen Testung eines bionischen und eines konventionellen Plattendesigns zur Versorgung von Kalkaneusfrakturen, insbesondere auf Stabilität und Materialermüdung, entwickelt. Die Versuche wurden an zwölf Platten, jeweils sechs der bionischen und sechs der konventionellen winkelstabilen Osteosynthesen, durchgeführt. Das ...
In der vorliegenden Arbeit wurde ein neuartiger Versuchsaufbau zur biomechanischen Testung eines bionischen und eines konventionellen Plattendesigns zur Versorgung von Kalkaneusfrakturen, insbesondere auf Stabilität und Materialermüdung, entwickelt. Die Versuche wurden an zwölf Platten, jeweils sechs der bionischen und sechs der konventionellen winkelstabilen Osteosynthesen, durchgeführt. Das bionische Plattendesign tolerierte eine signifikant längere Belastungszeit, eine signifikant höhere axiale Kraft und zeigte eine signifikant geringere Auslenkung unter zyklischer Belastung. Die neuartige Plattenarchitektur bietet eine höhere Stabilität und Belastbarkeit bei geringerer Materialermüdung verglichen mit dem konventionellen Plattendesign.
Translation of the abstract (English)
A novel approach was developed to biomechanically test bionic and conventional calcaneal plate designs for stability and fatigue. The test was conducted on twelve plates, six bionic plates and six standard locking calcaneal plates. Glass-fibre reinforced polyamide fixtures providing nearly physiological conditions were used. The bionic design showed significantly higher fatigue life, load to ...
A novel approach was developed to biomechanically test bionic and conventional calcaneal plate designs for stability and fatigue. The test was conducted on twelve plates, six bionic plates and six standard locking calcaneal plates. Glass-fibre reinforced polyamide fixtures providing nearly physiological conditions were used. The bionic design showed significantly higher fatigue life, load to failure and reduced displacement under cyclic load. The novel plate architecture offers higher stability and load tolerance while being more resistant to fatigue in our tests compared to the conventional plate design.
Involved Institutions
Details
| Item type | Thesis of the University of Regensburg (PhD) |
| Open Access Type: | Primary Publication |
|---|---|
| Date | 3 June 2014 |
| Referee | Prof. Dr. Bernd Kinner |
| Date of exam | 30 May 2014 |
| Institutions | Medicine > Lehrstuhl für Unfallchirurgie |
| Keywords | Kalkaneusfraktur, biomechanische Analyse, bionisches Plattendesign, Osteosynthese Kalkaneus |
| Dewey Decimal Classification | 600 Technology > 610 Medical sciences Medicine |
| Status | Published |
| Refereed | Yes, this version has been refereed |
| Created at the University of Regensburg | Yes |
| URN of the UB Regensburg | urn:nbn:de:bvb:355-epub-300613 |
| Item ID | 30061 |
Download Statistics
Download Statistics