Treutwein, Marius ; Hipp, Matthias ; Koelbl, Oliver ; Dobler, Barbara

Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Prostate - A Comparison of Flatness Filter Free (FFF) and Flat Beam Plans

Treutwein, Marius , Hipp, Matthias, Koelbl, Oliver und Dobler, Barbara (2016) Volumetric Modulated Arc Therapy (VMAT) Treatment Planning for Prostate - A Comparison of Flatness Filter Free (FFF) and Flat Beam Plans. Strahlentherapie und Onkologie 192 (Supp.1), S. 51.

Veröffentlichungsdatum dieses Volltextes: 06 Jun 2016 11:21
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.33720


Zusammenfassung

Introduction Linear accelerators (Linacs) with Flatness Filter Free (FFF) mode obtain a much higher dose rate by omitting the flatness filter. The resulting inhomogeneous dose distribution is compensated by fluence modulating techniques like IMRT or VMAT. This planning study compares VMAT plans for patients with prostate carcinoma. Optimizations were performed using both modes: flattened beam ...

Introduction
Linear accelerators (Linacs) with Flatness Filter Free (FFF) mode obtain a much higher dose rate by omitting the flatness filter. The resulting inhomogeneous dose distribution is compensated by fluence modulating techniques like IMRT or VMAT. This planning study compares VMAT plans for patients with prostate carcinoma. Optimizations were performed using both modes: flattened beam (FB) and FFF. The aim of this study is to evaluate the plan quality and the number of monitor units (MU).
Material and Methods
Data sets of 10 patients with localized prostate cancer and reliable dose volume objectives were used for this retrospective planning study. A simultaneous integrated boost radiation therapy aims at a minimum dose of 71.0Gy and maximum of 74.2Gy in the CTV and a minimum dose of 59.4Gy in the PTV in 33 fractions. The posterior rectum wall is limited to 50.0Gy. The median values of rectum and urinary bladder are set to 50.0Gy. Additionally the maximum dose to the rectum is set to 74.2Gy. The VMAT parameters in the treatment planning system (TPS) Oncentra® External Beam v4.5 are set to: Single Arc rotation (182°-178°), collimator 45°, maximum delivery time 110s, gantry spacing 4°, and collapsed cone algorithm. The linac Synergy Agility offers a dose rate of 550MU/min (FB) and 1700MU/min (FFF). The leaves have a width of 5mm projected to the isocenter.
The following parameters are evaluated: average dose DAv and homogeneity H = (D5–D95)/DAv in the CTV, minimum dose in the PTV represented by the D98PTV-CTV of the difference volume of PTV and CTV, maximum dose in the posterior rectum wall represented by the D2Rpost, median dose to rectum D50R and urinary bladder D50B, and the number of MU.
Results
Generally the dose volume statistics are very close for both modes. Taking the average dose in the CTV as normalization value, the maximum does not exceed 107%. The minimum dose in the PTV has been reached in one plan of each group only. The objectives for the median values in rectum and urinary bladder as well as maximum dose to the posterior rectum wall have been achieved in all cases. The only statistically significant difference for both groups is the number of MU which is about 10% lower for the FB plans.
Discussion
The plans for both modes show a good homogeneity in the CTV. The minimum dose to the PTV and the maximum dose to the posterior rectum wall are counterworking objectives which resulted in favour for the rectum for the given weights of the objectives. The high dose rate of the FFF mode aims at shorter treatment times which would reduce intrafractional organ motion. Measurements of the delivery times will be performed and discussed in the presentation.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftStrahlentherapie und Onkologie
Verlag:Springer Verlag
Band:192
Nummer des Zeitschriftenheftes oder des Kapitels:Supp.1
Seitenbereich:S. 51
Datum11 Juni 2016
Zusätzliche Informationen (Öffentlich)Präsentation bei der 22. Jahrestagung der Deutschen Gesellschaft für Radioonkologie (DEGRO) unter Mitwirkung der Österreichischen Gesellschaft für Radioonkologie, Radiobiologie und medizinische Radiophysik (ÖGRO). DOI und "Andere URL zum Volltext" beziehen sich auf den kompletten Tagungsband. Diese Arbeit wurde gefördert vom Bayerischen Staatsministerium für Umwelt und Verbraucherschutz.
InstitutionenMedizin > Lehrstuhl für Strahlentherapie
Identifikationsnummer
WertTyp
10.1007/s00066-016-0974-zDOI
Stichwörter / KeywordsProstate cancer, VMAT, Volumetric Modulated Arc Therapy, FFF, Flatness Filter Free
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 530 Physik
600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenJa
Dokumenten-ID33720

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben