Direkt zum Inhalt

Pregler, Benedikt ; Beyer, L. P. ; Teufel, A. ; Niessen, C. ; Stroszczynski, C. ; Brodoefel, H. ; Wiggermann, P.

Low Tube Voltage Liver MDCT with Sinogram-Affirmed Iterative Reconstructions for the Detection of Hepatocellular Carcinoma

Pregler, Benedikt, Beyer, L. P., Teufel, A., Niessen, C., Stroszczynski, C., Brodoefel, H. und Wiggermann, P. (2017) Low Tube Voltage Liver MDCT with Sinogram-Affirmed Iterative Reconstructions for the Detection of Hepatocellular Carcinoma. Scientific Reports 7 (1), S. 9460.

Veröffentlichungsdatum dieses Volltextes: 17 Jan 2018 14:53
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.36533


Zusammenfassung

Aim of this study was to compare low tube voltage computed tomography (80 kV) of the liver using iterative image reconstruction (SAFIRE) with standard computed tomography (120 kV) using filtered back-projection (FBP) for the detection of hepatocellular carcinoma (HCC). 46 patients (43 men) with 93 HCC confirmed by 3T MRI with Gd-EOB-DPTA, in inconclusive cases combined with contrast-enhanced ...

Aim of this study was to compare low tube voltage computed tomography (80 kV) of the liver using iterative image reconstruction (SAFIRE) with standard computed tomography (120 kV) using filtered back-projection (FBP) for the detection of hepatocellular carcinoma (HCC). 46 patients (43 men) with 93 HCC confirmed by 3T MRI with Gd-EOB-DPTA, in inconclusive cases combined with contrast-enhanced ultrasound, underwent dual-energy CT. The raw data of the 80 kV tube was reconstructed using the iterative reconstruction algorithm SAFIRE with two strengths (I3 and I5). The virtual 120 kV image data set was reconstructed using FBP. The CT images were reviewed to determine the lesion-to-liver contrast (LLC), the lesion contrast-to-noise ratio (CNR) and the sensitivity. The LLC (57.1/54.3 [I3/I5] vs. 34.9 [FBP]; p <= 0.01), CNR (3.67/4.45 [I3/I5] vs. 2.48 [FBP]; p < 0.01) and sensitivity (91.4%/88.2% [I3/I5] vs. 72.0% [FBP]; p <= 0.01) were significantly higher in the low-voltage protocol using SAFIRE. Therefore, low tube voltage CT using SAFIRE results in an increased lesion-to-liver contrast as well as an improved lesion contrast-to-noise ratio compared to FBP at 120 kV which results in a higher sensitivity for the detection of HCC.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftScientific Reports
Verlag:Nature
Ort der Veröffentlichung:LONDON
Band:7
Nummer des Zeitschriftenheftes oder des Kapitels:1
Seitenbereich:S. 9460
Datum25 August 2017
InstitutionenMedizin > Lehrstuhl für Innere Medizin I
Medizin > Lehrstuhl für Röntgendiagnostik
Identifikationsnummer
WertTyp
10.1038/s41598-017-10095-6DOI
Stichwörter / KeywordsABDOMINAL COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; IMAGE QUALITY; MULTIDETECTOR CT; PHANTOM; ALGORITHM; SAFIRE; NOISE; ANGIOGRAPHY;
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenJa
URN der UB Regensburgurn:nbn:de:bvb:355-epub-365330
Dokumenten-ID36533

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben