| Veröffentlichte Version Download ( PDF | 1MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test
Haimerl, Michael, Probst, Ute, Poelsterl, Stefanie, Beyer, Lukas
, Fellner, Claudia, Selgrad, Michael, Hornung, Matthias, Stroszczynski, Christian und Wiggermann, Philipp
(2018)
Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test.
Scientific Reports 8 (1).
Veröffentlichungsdatum dieses Volltextes: 30 Aug 2018 09:42
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.37673
Zusammenfassung
Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of C-13-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity ...
Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of C-13-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity (SI) values. 110 patients underwent Gd-EOB-DTPA-enhanced 3-T MRI and, for the evaluation of liver function, a C-13-methacetin breath test (C-13-MBT). SI values from before (SIpre) and 20 min after (SIpost) contrast media injection were acquired by T1-weighted volume-interpolated breath-hold examination (VIBE) sequences with fat suppression. The relative enhancement (RE) between the plain and contrast-enhanced SI values was calculated and evaluated in a correlation analysis of C-13-MBT values to SIpost and RE to obtain a SI-based estimation of C-13-MBT values. The simple regression model showed a log-linear correlation of C-13-MBT values with SIpost and RE (p < 0.001). Stratified by 3 different categories of C-13-MBT readouts, there was a constant significant decrease in both SIpost (p <= 0.002) and RE (p <= 0.033) with increasing liver disease progression as assessed by the C-13-MBT. Liver function as determined using real-time C-13-methacetin breath analysis can be estimated quantitatively from GdEOB- DTPA-enhanced MRI using SI-based indices.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Scientific Reports | ||||
| Verlag: | Nature | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | LONDON | ||||
| Band: | 8 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 1 | ||||
| Datum | 13 Juni 2018 | ||||
| Institutionen | Medizin > Lehrstuhl für Chirurgie Medizin > Lehrstuhl für Innere Medizin I Medizin > Lehrstuhl für Röntgendiagnostik | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | GD-EOB-DTPA; LIMAX TEST; ENHANCED MRI; HEPATIC-FUNCTION; CONTRAST AGENT; PARENCHYMAL ENHANCEMENT; CLINICAL-EVALUATION; FUNCTION CAPACITY; CIRRHOSIS; PHASE; | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Ja | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-376733 | ||||
| Dokumenten-ID | 37673 |
Downloadstatistik
Downloadstatistik