Direkt zum Inhalt

Haimerl, Michael ; Probst, Ute ; Poelsterl, Stefanie ; Beyer, Lukas ; Fellner, Claudia ; Selgrad, Michael ; Hornung, Matthias ; Stroszczynski, Christian ; Wiggermann, Philipp

Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test

Article

Haimerl, Michael, Probst, Ute, Poelsterl, Stefanie, Beyer, Lukas , Fellner, Claudia, Selgrad, Michael, Hornung, Matthias, Stroszczynski, Christian and Wiggermann, Philipp (2018) Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test. Scientific Reports 8 (1).

DOI to cite this document: 10.5283/epub.37673


Abstract

Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of C-13-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity ...

Gadoxetic acid (Gd-EOB-DTPA) is a paramagnetic MRI contrast agent with raising popularity and has been used for evaluation of imaging-based liver function in recent years. In order to verify whether liver function as determined by real-time breath analysis using the intravenous administration of C-13-methacetin can be estimated quantitatively from Gd-EOB-DTPA-enhanced MRI using signal intensity (SI) values. 110 patients underwent Gd-EOB-DTPA-enhanced 3-T MRI and, for the evaluation of liver function, a C-13-methacetin breath test (C-13-MBT). SI values from before (SIpre) and 20 min after (SIpost) contrast media injection were acquired by T1-weighted volume-interpolated breath-hold examination (VIBE) sequences with fat suppression. The relative enhancement (RE) between the plain and contrast-enhanced SI values was calculated and evaluated in a correlation analysis of C-13-MBT values to SIpost and RE to obtain a SI-based estimation of C-13-MBT values. The simple regression model showed a log-linear correlation of C-13-MBT values with SIpost and RE (p < 0.001). Stratified by 3 different categories of C-13-MBT readouts, there was a constant significant decrease in both SIpost (p <= 0.002) and RE (p <= 0.033) with increasing liver disease progression as assessed by the C-13-MBT. Liver function as determined using real-time C-13-methacetin breath analysis can be estimated quantitatively from GdEOB- DTPA-enhanced MRI using SI-based indices.



Involved Institutions


Details

Item typeArticle
Journal or Publication TitleScientific Reports
PublisherNature
Open Access TypeGold (with APC)
Place of PublicationLONDON
Volume8
Number of Issue or Book Chapter1
Date13 June 2018
Date of publication30 Aug 2018 09:42
InstitutionsMedicine > Lehrstuhl für Chirurgie
Medicine > Lehrstuhl für Innere Medizin I
Medicine > Lehrstuhl für Röntgendiagnostik
Identification Number
ValueType
10.1038/s41598-018-27401-5DOI
KeywordsGD-EOB-DTPA; LIMAX TEST; ENHANCED MRI; HEPATIC-FUNCTION; CONTRAST AGENT; PARENCHYMAL ENHANCEMENT; CLINICAL-EVALUATION; FUNCTION CAPACITY; CIRRHOSIS; PHASE;
Dewey Decimal Classification600 Technology > 610 Medical sciences Medicine
StatusPublished
RefereedYes, this version has been refereed
Created at the University of RegensburgYes
URN of the UB Regensburgurn:nbn:de:bvb:355-epub-376733
Item ID37673

Export bibliographical data

Owner only: item control page

nach oben