Efficiency of contrast enhanced ultrasound for immediate assessment of ablation status after intraoperative radiofrequency ablation of hepatic malignancies

da Silva, N. Platz Batista, Beyer, L.P., Hottenrott, M.C., Hackl, C., Schlitt, H.J., Stroszczynski, C., Wiggermann, P. and Jung, E.M. (2017) Efficiency of contrast enhanced ultrasound for immediate assessment of ablation status after intraoperative radiofrequency ablation of hepatic malignancies. Clinical Hemorheology and Microcirculation 66 (4), pp. 357-368.

Full text not available from this repository.

at publisher (via DOI)

Other URL: http://doi.org/10.3233/CH-179112


Abstract

AIM: To evaluate the efficiency of intraoperative contrast enhanced ultrasound (Io-CEUS) for assessment of radiofrequency ablation (RFA) during liver tumor surgery. MATERIAL AND METHODS: Retrospective analysis was performed on a total number of 18 patients out of over 500 patients who underwent combined liver tumor surgery and RFAof 27 hepatic tumors between 02/2011 and 12/2016. Io-CEUS was ...

plus


Export bibliographical data



Item type:Article
Date:2017
Institutions:Medicine > Lehrstuhl für Chirurgie
Medicine > Lehrstuhl für Röntgendiagnostik
Identification Number:
ValueType
10.3233/CH-179112DOI
Keywords:HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; EFSUMB GUIDELINES; LIVER METASTASES; SURGERY; ELASTOGRAPHY; LESIONS; CEUS; MICROVASCULARIZATION; RECOMMENDATIONS; CEUS; radiofrequency ablation; liver surgery; intraoperative ultrasound
Dewey Decimal Classification:600 Technology > 610 Medical sciences Medicine
Status:Published
Refereed:Yes, this version has been refereed
Created at the University of Regensburg:Yes
Item ID:38865