Item type: | Article | ||||
---|---|---|---|---|---|
Journal or Publication Title: | RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren | ||||
Publisher: | GEORG THIEME VERLAG KG | ||||
Place of Publication: | STUTTGART | ||||
Volume: | 188 | ||||
Number of Issue or Book Chapter: | 06 | ||||
Page Range: | pp. 566-573 | ||||
Date: | 2016 | ||||
Institutions: | Medicine > Lehrstuhl für Strahlentherapie | ||||
Identification Number: |
| ||||
Keywords: | ATRIAL SEPTAL OCCLUDER; PERCUTANEOUS RETRIEVAL; FOREIGN-BODIES; VENOUS CATHETERIZATION; PULMONARY-ARTERY; SURGICAL REMOVAL; ACCESS SYSTEMS; COMPLICATIONS; EXPERIENCE; PORT; angiography; interventional procedures; safety; technical aspects | ||||
Dewey Decimal Classification: | 600 Technology > 610 Medical sciences Medicine | ||||
Status: | Published | ||||
Refereed: | Yes, this version has been refereed | ||||
Created at the University of Regensburg: | Yes | ||||
Item ID: | 42137 |
Abstract
Purpose: Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. Material and Methods: Between 1999 and 2015 38 patients (21 female; 17 male; Age: 17 -92; Average 54.3 years) underwent an extraction of intravascular dislocated foreign bodies, which were not lost during a radiological intervention. The extracted material included 29 port ...

Abstract
Purpose: Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. Material and Methods: Between 1999 and 2015 38 patients (21 female; 17 male; Age: 17 -92; Average 54.3 years) underwent an extraction of intravascular dislocated foreign bodies, which were not lost during a radiological intervention. The extracted material included 29 port catheters, 3 tips of tunneled dialysis catheters, 2 stents, 2 guide wires, 1 CVC tip and 1 AS occluder device. Various catheters for repositioning and extraction were used. The access was transarterial as well as transvenous. Technical success was defined as complete removal of the foreign body. Results: The technical success rate was 92.1 % (35 of 38). In 17 patients an additional catheter was necessary to reposition the foreign body in order to make it accessible for the extraction catheter. In one case a stent was relocated and remodeled within the patient and was not extracted. In another case we experienced a dislocation of a small fragment of the port catheter into the distal parts of the pulmonary artery, which couldn't be extracted. A guide wire could not be extracted as it was already adhered with the vessel wall. Peri-interventional complications were not documented. Conclusion: The percutaneous extraction of dislocated intravascular foreign bodies is technically successful and poor of complications. Interventional therapy can avoid surgical removal. Key points: The percutaneous extraction of dislocated intravascular foreign bodies is technically successful and safe. In most cases surgical removal can be avoided. The gooseneck-snare catheter was mainly used for the extraction of intravascular foreign bodies. Citation Format: Ayx I, Goessmann H, Hubauer H et al. Interventional Removal of Intravascular Medical Devices: Methods and Technical Success. Fortschr Rontgenstr 2016; 188: 566-573