Direkt zum Inhalt

Sari, Tuğrul ; Usumez, Aslihan ; Strasser, Thomas Martin ; Şahinbas, Abdurrahman ; Rosentritt, Martin

Temporary materials: comparison of in vivo and in vitro performance

Sari, Tuğrul, Usumez, Aslihan, Strasser, Thomas Martin, Şahinbas, Abdurrahman und Rosentritt, Martin (2020) Temporary materials: comparison of in vivo and in vitro performance. Clinical Oral Investigations 24, S. 4061-4068.

Veröffentlichungsdatum dieses Volltextes: 18 Mrz 2021 07:12
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.45226


Zusammenfassung

Objective The aim of this investigation was to compare clinical performance and in vitro wear of temporary CAD/CAM and cartridge crowns. This study is an approach to estimate the influence of in vivo use and laboratory simulation on temporary crowns. Materials and methods A total of 90 crowns were fabricated from each temporary CAD/CAM or cartridge material. Also, 10 crowns of each material were ...

Objective The aim of this investigation was to compare clinical performance and in vitro wear of temporary CAD/CAM and cartridge crowns. This study is an approach to estimate the influence of in vivo use and laboratory simulation on temporary crowns. Materials and methods A total of 90 crowns were fabricated from each temporary CAD/CAM or cartridge material. Also, 10 crowns of each material were clinically applied for 14 days, and 80 identical duplicate restorations were investigated in the laboratory after storage in water (14 days; 37 degrees C) and subsequent thermal cycling and mechanical loading (TCML, 240.000 x 50N ML, 600 x 5 degrees C/55 degrees C). After in vivo application or in vitro aging, facture force, superficial wear (mean and maximum), surface roughness (Ra, Rz), thermal weight loss (TGA), and heat of reaction (DSC) were determined for all crowns. Statistics: Bonferroni post hoc test; one-way analysis of variance (ANOVA);alpha = 0.05). Results The fracture resistance of the temporary materials varied between 1196.4 (CAD in vivo) and 1598.3 N (cartridge crown in vitro). Mean (maximum) wear data between 204.7 (386.7 mu m; cartridge in vitro) and 353.0 mu m (621.8 mu m; CAD in vitro) were found. Ra values ranged between 4.4 and 4.9 mu m and Rz values between 36.0 and 40.8 mu m. DSC and TG analysis revealed small differences between the materials but a strong influence of the aging process. Conclusions Comparison of in vivo and in vitro aging led to no significant differences in fracture force and wear but differences in roughness, DSC, and TGA. SEM evaluation confirmed comparability. Comparison of CAD/CAM and cartridge temporary materials partially showed significant differences.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftClinical Oral Investigations
Verlag:SPRINGER HEIDELBERG
Ort der Veröffentlichung:HEIDELBERG
Band:24
Seitenbereich:S. 4061-4068
DatumJuni 2020
InstitutionenMedizin > Lehrstuhl für Zahnärztliche Prothetik
Identifikationsnummer
WertTyp
10.1007/s00784-020-03278-5DOI
Stichwörter / KeywordsFIXED PARTIAL DENTURES; FRACTURE-RESISTANCE; RESIN; TEMPERATURE; CAD/CAM; CROWN; Temporary materials; Provisional materials; In vitro testing; In vivo investigation; TCML; Roughness; Wear; Fracture force
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-452265
Dokumenten-ID45226

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben