Purpose: In contrast to total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA) is a true resurfacing procedure, as none of the ligaments are replaced or released, and the pre-arthritic leg alignment is the major goal. As such, the alignment of the tibial component plays a crucial role in postoperative knee function and long-term survival. Pinless navigation has shown reliable ...

Purpose: In contrast to total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA) is a true resurfacing procedure, as none of the ligaments are replaced or released, and the pre-arthritic leg alignment is the major goal. As such, the alignment of the tibial component plays a crucial role in postoperative knee function and long-term survival. Pinless navigation has shown reliable results in total knee arthroplasty. To the best of our knowledge, the use of pinless navigation has not been investigated for UKA. Therefore, the present study investigated whether implantation of the tibial component in 3 degrees varus, which is closer to the anatomical axis, is feasible with a pinless optical navigation system. Methods: 60 patients with the diagnosis of an unicompartmental arthritis, were eligible for UKA and treated with implantation in 3 degrees varus alignment of the tibial component. Two groups were established. In the treatment group the tibial component was aligned using a pinless navigation technique. In the control group, a conventional extramedullary alignment guide was used. A clinical and radiographic follow up took place within 1 year of operation. Results: 57 Patients were eligible for analysis. No clinical incidents were noted in the follow up period. The desired target value, the position of the tibial component, was accurately achieved with an average of 3 degrees medial inclination using the pinless navigation as well as using the conventional technique. Mean incision to suture time was negligible between the two techniques. The mean suture time was 43.2 min with pinless navigation and 42.7 min with the conventional technique. Conclusions: With pinless navigation in UKA, a method was presented that made it possible to achieve sled prosthesis alignment at the level of a high-volume surgeon. These results were achieved with an irrelevant increase of surgical time and without placement of pins.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftJournal of Clinical Medicine
Verlag:MDPI
Ort der Veröffentlichung:BASEL
Band:2021
Nummer des Zeitschriftenheftes oder des Kapitels:10
Seitenbereich:S. 2422
Datum30 Mai 2021
InstitutionenMedizin > Lehrstuhl für Unfallchirurgie
Identifikationsnummer
WertTyp
10.3390/jcm10112422DOI
Stichwörter / KeywordsALIGNMENT; OUTCOMES; knee arthroplasty; unicompartmental; navigation; pinless
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenJa
URN der UB Regensburgurn:nbn:de:bvb:355-epub-458792
Dokumenten-ID45879

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben