| Veröffentlichte Version Download ( PDF | 1MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Pinless Navigation in Unicompartmental Knee Arthroplasty
Keuntje-Perka, Sarah, von Roth, Philipp, Worlicek, Michael, Koch, Matthias, Alt, Volker und Kaiser, Moritz (2021) Pinless Navigation in Unicompartmental Knee Arthroplasty. Journal of Clinical Medicine 2021 (10), S. 2422.Veröffentlichungsdatum dieses Volltextes: 25 Jun 2021 15:58
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.45879
Zusammenfassung
Purpose: In contrast to total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA) is a true resurfacing procedure, as none of the ligaments are replaced or released, and the pre-arthritic leg alignment is the major goal. As such, the alignment of the tibial component plays a crucial role in postoperative knee function and long-term survival. Pinless navigation has shown reliable ...
Purpose: In contrast to total knee arthroplasty (TKA), unicompartmental knee arthroplasty (UKA) is a true resurfacing procedure, as none of the ligaments are replaced or released, and the pre-arthritic leg alignment is the major goal. As such, the alignment of the tibial component plays a crucial role in postoperative knee function and long-term survival. Pinless navigation has shown reliable results in total knee arthroplasty. To the best of our knowledge, the use of pinless navigation has not been investigated for UKA. Therefore, the present study investigated whether implantation of the tibial component in 3 degrees varus, which is closer to the anatomical axis, is feasible with a pinless optical navigation system. Methods: 60 patients with the diagnosis of an unicompartmental arthritis, were eligible for UKA and treated with implantation in 3 degrees varus alignment of the tibial component. Two groups were established. In the treatment group the tibial component was aligned using a pinless navigation technique. In the control group, a conventional extramedullary alignment guide was used. A clinical and radiographic follow up took place within 1 year of operation. Results: 57 Patients were eligible for analysis. No clinical incidents were noted in the follow up period. The desired target value, the position of the tibial component, was accurately achieved with an average of 3 degrees medial inclination using the pinless navigation as well as using the conventional technique. Mean incision to suture time was negligible between the two techniques. The mean suture time was 43.2 min with pinless navigation and 42.7 min with the conventional technique. Conclusions: With pinless navigation in UKA, a method was presented that made it possible to achieve sled prosthesis alignment at the level of a high-volume surgeon. These results were achieved with an irrelevant increase of surgical time and without placement of pins.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Journal of Clinical Medicine | ||||
| Verlag: | MDPI | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | BASEL | ||||
| Band: | 2021 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 10 | ||||
| Seitenbereich: | S. 2422 | ||||
| Datum | 30 Mai 2021 | ||||
| Institutionen | Medizin > Lehrstuhl für Unfallchirurgie | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | ALIGNMENT; OUTCOMES; knee arthroplasty; unicompartmental; navigation; pinless | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Ja | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-458792 | ||||
| Dokumenten-ID | 45879 |
Downloadstatistik
Downloadstatistik