Direkt zum Inhalt

Owner only: item control page
Radeck, Viola ; Helbig, Horst ; Prahs, Philipp

Subretinale Lufteingabe zur Behandlung postoperativer Netzhautfalten nach Ablatio
Subretinal air injection for treatment of retinal folds after retinal detachment surgery

Radeck, Viola , Helbig, Horst and Prahs, Philipp (2021) Subretinale Lufteingabe zur Behandlung postoperativer Netzhautfalten nach Ablatio
Subretinal air injection for treatment of retinal folds after retinal detachment surgery.
Der Ophthalmologe 119, pp. 381-387.

Date of publication of this fulltext: 09 Sep 2021 04:19
Article
DOI to cite this document: 10.5283/epub.49243


Abstract

Background Full-thickness retinal folds are an unpleasant complication after vitrectomy or buckle surgery with gas tamponade for the treatment of retinal detachment. If the retinal folds involve the macula, the visual function of the patients will be severely impaired. This article describes a surgical technique for the management of such full-thickness macular folds. Method Between January 2017 ...

Background Full-thickness retinal folds are an unpleasant complication after vitrectomy or buckle surgery with gas tamponade for the treatment of retinal detachment. If the retinal folds involve the macula, the visual function of the patients will be severely impaired. This article describes a surgical technique for the management of such full-thickness macular folds. Method Between January 2017 and June 2020 a total of 6 patients were treated with the following technique. A redetachment was induced with balanced salt solution (BSS), followed by a subretinal air injection with filtered air. The retinal fold was mechanically smoothed out with the aid of perfluorocarbon (PFC). A postoperative drainage of air and BSS was not necessary due to spontaneous resorption. Results None of the patients experienced visual loss after redetachment of the retina. The visual acuity improved in 4 of the 6 patients, perception of metamorphopsia improved in 5 out of 6 patients, 2 reported complete disappearance of metamorphopsia and in 1 patient distorted vision was unchanged despite an anatomically smoothed central retina after surgery. Conclusion With careful consideration of the indications, this surgical technique has shown to be a safe and promising therapeutic strategy for the treatment of macular full-thickness retinal folds after retinal detachment surgery.



Involved Institutions


Details

Item typeArticle
Journal or Publication TitleDer Ophthalmologe
Publisher:SPRINGER HEIDELBERG
Open Access Type:DEAL (Springer)
Place of Publication:HEIDELBERG
Volume:119
Page Range:pp. 381-387
Date30 August 2021
InstitutionsMedicine > Lehrstuhl für Augenheilkunde
Identification Number
ValueType
10.1007/s00347-021-01485-3DOI
KeywordsMACULAR FOLD; REPAIR; Macular fold; Retinal fold; Retinal detachment surgery; Metamorphopsia; Retinal shift
Dewey Decimal Classification600 Technology > 610 Medical sciences Medicine
StatusPublished
RefereedYes, this version has been refereed
Created at the University of RegensburgYes