Direkt zum Inhalt

Simma, Alexander ; Potapow, Antonia ; Brandstetter, Susanne ; Michel, Holger ; Melter, Michael ; Seelbach-Göbel, Birgit ; Apfelbacher, Christian J. ; Kabesch, Michael ; Gerling, Stephan

Electrocardiographic Screening in the First Days of Life for Diagnosing Long QT Syndrome: Findings from a Birth Cohort Study in Germany

Simma, Alexander, Potapow, Antonia, Brandstetter, Susanne , Michel, Holger, Melter, Michael , Seelbach-Göbel, Birgit, Apfelbacher, Christian J. , Kabesch, Michael und Gerling, Stephan (2020) Electrocardiographic Screening in the First Days of Life for Diagnosing Long QT Syndrome: Findings from a Birth Cohort Study in Germany. Neonatology 117 (6), S. 756-763.

Veröffentlichungsdatum dieses Volltextes: 11 Okt 2021 12:40
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.49517


Zusammenfassung

Introduction: Newborn sudden infant death syndrome (SIDS) has failed to decrease in the last decades, and a third of the neonatal cases occurred within the first 6 days of life. The long QT syndrome (LQTS) is a genetic disease with a prevalence of 1 in 2,000 live births and contributes to almost 10% of SIDS cases. Early identification of LQTS through electrocardiogram (ECG) screening is likely to ...

Introduction: Newborn sudden infant death syndrome (SIDS) has failed to decrease in the last decades, and a third of the neonatal cases occurred within the first 6 days of life. The long QT syndrome (LQTS) is a genetic disease with a prevalence of 1 in 2,000 live births and contributes to almost 10% of SIDS cases. Early identification of LQTS through electrocardiogram (ECG) screening is likely to reduce mortality. Methods and Results: In this ongoing prospective study we evaluated 2,251 ECGs from newborns participating in the KUNO Kids birth cohort study between July 2015 and July 2018. ECGs were recorded at a mean age of 2.0 days (IQR 0 days). The QT interval was corrected for heart rate using Bazett's formula (QTc). A QTc between 451 and 460, 461-470, and >470 ms was measured in 23 (1.0), 14 (0.6), and 62 (2.8%) participants, respectively. Fourteen neonates (0.62%) were admitted and monitored because their initial QTc was >= 500 ms. In 2 genetically analyzed participants, a mutation was found. One disease-causing for LQTS type 1 and the other of unclear significance. Cascade screening revealed affected members in both families. Conclusion: A standardized neonatal ECG screening in the first days of life is able to identify neonates with a relevant transient form of prolonged QT intervals and to aid diagnosing congenital LQTS.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftNeonatology
Verlag:KARGER
Ort der Veröffentlichung:BASEL
Band:117
Nummer des Zeitschriftenheftes oder des Kapitels:6
Seitenbereich:S. 756-763
DatumNovember 2020
InstitutionenMedizin > Lehrstuhl für Frauenheilkunde und Geburtshilfe (Schwerpunkt Geburtshilfe)
Medizin > Lehrstuhl für Kinder- und Jugendmedizin
Identifikationsnummer
WertTyp
10.1159/000511572DOI
Stichwörter / KeywordsDEATH; INTERVAL; PROLONGATION; PHENOTYPE; Sudden infant death; Electrocardiography screening; Long QT syndrome; Newborn; Birth cohort
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-495179
Dokumenten-ID49517

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben