Direkt zum Inhalt

Taxis, Juergen ; Ungerboeck, Lena ; Motel, Constantin ; Eckert, Alexander W. ; Platz Batista da Silva, Natascha ; Nieberle, Felix ; Ludwig, Nils ; Meier, Johannes K. ; Ettl, Tobias ; Reichert, Torsten E. ; Spoerl, Steffen

Thin PDS Foils Represent an Equally Favorable Restorative Material for Orbital Floor Fractures Compared to Titanium Meshes

Taxis, Juergen , Ungerboeck, Lena, Motel, Constantin, Eckert, Alexander W., Platz Batista da Silva, Natascha, Nieberle, Felix, Ludwig, Nils , Meier, Johannes K., Ettl, Tobias, Reichert, Torsten E. und Spoerl, Steffen (2023) Thin PDS Foils Represent an Equally Favorable Restorative Material for Orbital Floor Fractures Compared to Titanium Meshes. Tomography 9 (4), S. 1515-1525.

Veröffentlichungsdatum dieses Volltextes: 28 Aug 2023 10:06
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.54642


Zusammenfassung

Orbital floor fractures (OFFs) are common injuries of the midface and may result in long-term complications. The aim of this study was to compare two restoration materials, PDS foils and titanium meshes, with regards to (1) clinical outcome and (2) reduction in orbital volume. The monocentric discovery cohort was analyzed retrospectively and included 476 patients with OFFs treated between 2010 ...

Orbital floor fractures (OFFs) are common injuries of the midface and may result in long-term complications. The aim of this study was to compare two restoration materials, PDS foils and titanium meshes, with regards to (1) clinical outcome and (2) reduction in orbital volume. The monocentric discovery cohort was analyzed retrospectively and included 476 patients with OFFs treated between 2010 and 2020. A subcohort of 104 patients (study cohort) with isolated OFFs and available high-resolution imaging material was used for volume measurements. Postoperative complications were not significantly different between patients treated with different restoration materials. Prevalence of revision surgery was significantly higher in patients treated with thick PDS foils (25 mm). OFFs treated with PDS foils and titanium meshes showed a significant reduction in orbital volume (p = 0.0422 and p = 0.0056, respectively), however, this volume decrease was significantly less pronounced in patients treated with PDS foils alone (p = 0.0134). Restoration using PDS foil in an isolated OFF reduces the orbital volume to a lesser extent than titanium mesh. Class III patients according to the classification of Jaquiery with a missing bony ledge medial to the infraorbital fissure particularly benefit from restoration with PDS foils due to a lower reduction in the orbital volume. Regarding short- and long-term postoperative complications, a PDS foil thickness of 0.15 mm appears equivalent to titanium mesh in the treatment of OFFs.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftTomography
Verlag:MDPI
Ort der Veröffentlichung:BASEL
Band:9
Nummer des Zeitschriftenheftes oder des Kapitels:4
Seitenbereich:S. 1515-1525
Datum16 August 2023
InstitutionenMedizin > Lehrstuhl für Mund-, Kiefer- und Gesichtschirurgie
Medizin > Lehrstuhl für Röntgendiagnostik
Identifikationsnummer
WertTyp
10.3390/tomography9040121DOI
Stichwörter / KeywordsBLOWOUT FRACTURES; RECONSTRUCTION; ENOPHTHALMOS; orbital floor fracture; orbital volume analysis; three-dimensional measurement; PDS foil; titanium mesh
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenJa
URN der UB Regensburgurn:nbn:de:bvb:355-epub-546422
Dokumenten-ID54642

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben