| Veröffentlichte Version Download ( PDF | 2MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Aging and Fracture Resistance of Implant-Supported Molar Crowns with a CAD/CAM Resin Composite Veneer Structure
Rauch, Angelika, Heinzmann, Wendy, Rosentritt, Martin
, Hahnel, Sebastian, Schmidt, Michael Benno, Fuchs, Florian und Koenig, Andreas
(2023)
Aging and Fracture Resistance of Implant-Supported Molar Crowns with a CAD/CAM Resin Composite Veneer Structure.
Journal of Clinical Medicine 12 (18), S. 5997.
Veröffentlichungsdatum dieses Volltextes: 19 Sep 2023 14:42
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.54726
Zusammenfassung
Chipping of implant-supported molar crowns (iSCs) is a frequently reported complication. This study aimed to investigate the in-vitro aging and fracture resistance of iSCs with a CAD/CAM resin composite veneer structure fabricated with the Rapid Layer Technology (RLT) approach. Eight iSCs per group were fabricated by using two different CAD/CAM resin composites (Shofu Block HC: SH; Grandio blocs: ...
Chipping of implant-supported molar crowns (iSCs) is a frequently reported complication. This study aimed to investigate the in-vitro aging and fracture resistance of iSCs with a CAD/CAM resin composite veneer structure fabricated with the Rapid Layer Technology (RLT) approach. Eight iSCs per group were fabricated by using two different CAD/CAM resin composites (Shofu Block HC: SH; Grandio blocs: GB) for veneer structures, and zirconia (ZrO2), polyetheretherketone (PEEK), and cobalt-chromium (CoCr; control) as framework materials. The surfaces to be bonded were sandblasted, cleaned in an ultrasonic bath, and a coupling agent was applied. A self-adhesive resin luting composite was used to adhesively lute the veneer structures to the frameworks. The crowns were semi-permanently cemented to the abutments. After storage in deionized water, iSCs were loaded in a chewing simulator (TCML, 10,000 thermal cycles 5 degrees C to 55 degrees C for 20 s, 1.2 million, loading force 50 N). Four ZrO2 and one CoCr crown did not survive the TCML. The fracture force was determined after 24 h storage in deionized water and yielded values of >= 974 N. Lowest fracture forces were yielded in the PEEK-SH group in comparison to CoCr or ZrO2 groups (p <= 0.031). For identical framework materials, no significant influence of the veneering material was observed. All PEEK-GB frameworks fractured, and chipping occurred for ZrO2-SH and all CoCr frameworks. PEEK-SH and ZrO2-GB presented both chipping and framework fractures. Within the limitations of this in-vitro study, the RLT with a CAD/CAM resin composite veneer structure might be a promising approach to veneer iSCs. Yet, the choice of the CAD/CAM resin composite and of the framework material determine the fracture resistance.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Journal of Clinical Medicine | ||||
| Verlag: | MDPI | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | BASEL | ||||
| Band: | 12 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 18 | ||||
| Seitenbereich: | S. 5997 | ||||
| Datum | 15 September 2023 | ||||
| Institutionen | Medizin > Lehrstuhl für Zahnärztliche Prothetik | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | IN-VITRO FATIGUE; ZIRCONIA CROWNS; MODULUS; chipping; Cad-on; dental ceramic; PEEK; polymers; digital veneering | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Ja | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-547269 | ||||
| Dokumenten-ID | 54726 |
Downloadstatistik
Downloadstatistik