| Item type: | Article | ||||
|---|---|---|---|---|---|
| Journal or Publication Title: | Journal of Endovascular Therapy | ||||
| Publisher: | SAGE Publications | ||||
| Place of Publication: | THOUSAND OAKS | ||||
| Volume: | 28 | ||||
| Number of Issue or Book Chapter: | 6 | ||||
| Page Range: | pp. 871-877 | ||||
| Date: | 2021 | ||||
| Institutions: | Medicine > Abteilung für Gefäßchirurgie | ||||
| Identification Number: |
| ||||
| Keywords: | ATHEROSCLEROTIC ULCERS; NATURAL-HISTORY; endovascular aortic repair; balloon-expandable stent-grafts; penetrating aortic ulcer; atherosclerosis; off-label | ||||
| Dewey Decimal Classification: | 600 Technology > 610 Medical sciences Medicine | ||||
| Status: | Published | ||||
| Refereed: | Yes, this version has been refereed | ||||
| Created at the University of Regensburg: | Yes | ||||
| Item ID: | 56509 |
Abstract
Purpose To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). Materials and Methods Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. ...

Abstract
Purpose To describe the use of large-diameter balloon-expandable stent-grafts (BeGraft aortic stent-graft, Bentley InnoMed GmbH, Hechingen, Germany) in the treatment of infrarenal penetrating aortic ulcer (iPAU). Materials and Methods Retrospective analysis of patients undergoing endovascular treatment with the BeGraft aortic stent-graft in 8 European centers from January 2017 to October 2020. Demographics, perioperative data, and midterm outcomes were collected. Endpoints of the study were technical feasibility, early mortality, and morbidity. Results A total of 40 patients were included. The mean age was 73.9 +/- 7.05 years and 63.2% were male. Indications for treatment included size and morphology (65%), presence of symptoms (29.5%), and contained ruptures (5.5%). Urgent treatment was performed in 5% of cases. Technical success was 97.5%. Median operation time was 58 minutes (19-170 minutes), with 27.5% of patients having additional procedures during the main intervention (1 additional repair with a C-TAG (W.L. Gore & Associates, Inc, Flagstaff, AZ, USA) thoracic endoprosthesis, 5 covered endovascular reconstruction of aortic bifurcation procedures, 3 extensions with proximal cuffs, and 2 percutaneous angioplasties of the common iliac arteries). Percutaneous femoral access was used in 72.5%, while groin cut-down was performed in 27.5%. Repair was successful with only 1 stent in 45% of cases, while 37.5% required 2 stents and nearly 17.5% required 3/4 stent-grafts. The 30-day mortality was 0%, with a 2.5% reintervention rate (1 patient required evacuation of an intra-abdominal hematoma). Median follow-up was 13.9 months (2-39 months), during which no vascular-related reinterventions or deaths were reported. In 4 patients, a type II endoleak was observed. No cases of graft migration, thrombosis, or stent-fracture were observed. Conclusions The treatment of iPAU with the BeGraft aortic stent-graft in a selective patient group is feasible with low rate of perioperative morbidity and mortality. Balloon-expandable stent-grafts offer the option to repair iPAUs with a shorter coverage of the aorta using low-profile sheath, that enables treatment in the presence of calcified access vessels and small diameter aortic bifurcations.
Metadata last modified: 29 Feb 2024 12:28

Altmetric