| Veröffentlichte Version Download ( PDF | 1MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Polyethylene liner dissociation in total hip arthroplasty: a retrospective case–control study on a single implant design
Pagano, S.
, Plate, J. F., Kappenschneider, T., Reinhard, J., Scharf, M. und Maderbacher, G.
(2024)
Polyethylene liner dissociation in total hip arthroplasty: a retrospective case–control study on a single implant design.
Journal of Orthopaedics and Traumatology 25 (1).
Veröffentlichungsdatum dieses Volltextes: 20 Aug 2024 09:12
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.58951
Zusammenfassung
Background Modular acetabular components for total hip arthroplasty (THA) provide intraoperative flexibility; however, polyethylene liner dissociation may occur. This study aimed to examine the incidence and causes of liner dissociation associated with a specific acetabular component design at a single centre. Materials and methods A retrospective analysis of 7027 patients who underwent ...
Background
Modular acetabular components for total hip arthroplasty (THA) provide intraoperative flexibility; however, polyethylene liner dissociation may occur. This study aimed to examine the incidence and causes of liner dissociation associated with a specific acetabular component design at a single centre.
Materials and methods
A retrospective analysis of 7027 patients who underwent primary THA was performed to identify isolated liner dislocations. Patient demographics, clinical presentations, surgical and implant details, and both radiographic and computed tomography (CT) findings were analysed. Patients with liner dislocation were matched to a control group via 2:1 propensity score matching, and a logistic regression analysis was employed to identify associated risk factors.
Results
A total of 32 patients (0.45%) experienced liner dislocation at a mean 71.47 ± 60.10 months post surgery. Significant factors contributing to dislocations included the use of a conventional compared with a highly crosslinked polyethylene component (p = 0.049) and screw fixation (p = 0.028). Radiographic and CT analysis highlighted the importance of proper component orientation, revealing that patients experiencing dislocations demonstrated significantly lower acetabular cup anteversion angles (p = 0.001) compared with the control group. Impingement and malposition, identified in 41% and 47% of the cases, respectively, further underscored the multifactorial nature of dislocation risks.
Conclusions
While the overall rate of polyethylene liner dislocation was low, the findings of this study highlight the importance of appropriate cup placement to decrease the risk of dissociation. It further substantiates the influence of impingement and malposition in liner displacement, with increased mechanical stress exerted on the locking mechanism under adverse conditions and the potential risk increase due to screw placement.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Journal of Orthopaedics and Traumatology | ||||
| Verlag: | Springer | ||||
|---|---|---|---|---|---|
| Band: | 25 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 1 | ||||
| Datum | 14 August 2024 | ||||
| Institutionen | Medizin > Lehrstuhl für Orthopädie | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | Total hip arthroplasty, Liner dislocation, Polyethylene, Modularity, Component positioning, Case–control study | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Zum Teil | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-589513 | ||||
| Dokumenten-ID | 58951 |
Downloadstatistik
Downloadstatistik