| Item type: | Article | ||||
|---|---|---|---|---|---|
| Journal or Publication Title: | Journal of Cardiovascular Magnetic Resonance | ||||
| Publisher: | BMC | ||||
| Place of Publication: | LONDON | ||||
| Volume: | 14 | ||||
| Number of Issue or Book Chapter: | 1 | ||||
| Page Range: | p. 63 | ||||
| Date: | 2012 | ||||
| Institutions: | Medicine > Lehrstuhl für Innere Medizin II | ||||
| Identification Number: |
| ||||
| Keywords: | EMISSION-COMPUTED-TOMOGRAPHY; NONINVASIVE DETECTION; RANDOMIZED-TRIAL; STRESS PERFUSION; PROGNOSTIC VALUE; ANGIOGRAPHY; CONTRAST; ISCHEMIA; WOMEN; INTERVENTION; Cardiovascular magnetic resonance; Scintigraphy; Coronary disease; Perfusion; Ischemia | ||||
| Dewey Decimal Classification: | 600 Technology > 610 Medical sciences Medicine | ||||
| Status: | Published | ||||
| Refereed: | Yes, this version has been refereed | ||||
| Created at the University of Regensburg: | Yes | ||||
| Item ID: | 63382 |
Abstract
Background: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various ...

Abstract
Background: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. Methods: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. Results: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). Conclusion: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging.
Metadata last modified: 19 Dec 2024 09:35
Altmetric