| Item type: | Article | ||||
|---|---|---|---|---|---|
| Journal or Publication Title: | Journal of Neurosurgical Anesthesiology | ||||
| Publisher: | LIPPINCOTT WILLIAMS & WILKINS | ||||
| Place of Publication: | PHILADELPHIA | ||||
| Volume: | 22 | ||||
| Number of Issue or Book Chapter: | 4 | ||||
| Page Range: | pp. 288-295 | ||||
| Date: | 2010 | ||||
| Institutions: | Medicine > Lehrstuhl für Neurochirurgie | ||||
| Identification Number: |
| ||||
| Keywords: | CEREBRAL-BLOOD-FLOW; SOMATOSENSORY-EVOKED POTENTIALS; NEAR-INFRARED SPECTROSCOPY; TRANSCRANIAL DOPPLER; STUMP PRESSURE; REGIONAL ANESTHESIA; GENERAL-ANESTHESIA; SELECTING PATIENTS; RANDOMIZED-TRIAL; ENDARTERECTOMY; carotid endarterectomy; neuromonitoring; regional anesthesia; general anesthesia | ||||
| Dewey Decimal Classification: | 600 Technology > 610 Medical sciences Medicine | ||||
| Status: | Published | ||||
| Refereed: | Yes, this version has been refereed | ||||
| Created at the University of Regensburg: | Yes | ||||
| Item ID: | 65724 |
Abstract
Background: Diagnostic accuracy studies of neuromonitoring devices during carotid endarterectomy in awake patients are limited by the question of the transferability to anesthetized patients. This study was designed to compare the different neuromonitoring parameters in patients under regional and general anesthesia with stump pressure as the primary endpoint and the courses of cerebral blood ...

Abstract
Background: Diagnostic accuracy studies of neuromonitoring devices during carotid endarterectomy in awake patients are limited by the question of the transferability to anesthetized patients. This study was designed to compare the different neuromonitoring parameters in patients under regional and general anesthesia with stump pressure as the primary endpoint and the courses of cerebral blood flow velocity (Vmca) measured by transcranial Doppler sonography, regional cerebral oxygen saturation (rSO(2)) measured by near-infrared spectroscopy, and the amplitude of somatosensory evoked potentials (SEP) as the secondary endpoints. Materials and Methods: Ninety-six patients undergoing carotid endarterectomy were randomized to regional (n = 48) or sevoflurane/fentanyl anesthesia (n = 48) group. Absolute and relative changes of Vmca and rSO(2) and the SEP amplitude were recorded at baseline, during carotid artery clamping, and after declamping. Intergroup differences (beta) were calculated by generalized estimation equations and linear regression analysis. Results: Mean arterial pressure (P < 0.001) and heart rate (P < 0.001) were significantly higher in the regional anesthesia group. SP did not differ between both the groups (beta = - 1.6; P = 0.71). Vmca (beta = 9.2; P < 0.01) and rSO(2) (beta = 4.1; P < 0.01) values were higher in the awake patients. After adjustment for mean arterial pressure, the differences of Vmca remained consistent (beta = 9.3; P < 0.01) whereas these of rSO(2) during clamping (beta = 2.9; P = 0.105) and during reperfusion (beta = 2.7; P = 0.095) disappeared. No significant differences were found for Vmca(%) (beta = - 1.0; P = 0.80), rSO(2)(%) (beta = - 1.4; P = 1.8) and SEP (beta = - 2.6; P = 0.29). Conclusion: Carotid artery clamping leads to similar results of stump pressure and similar relative changes of transcranial Doppler sonography, near-infrared spectroscopy, and SEP monitoring in patients under regional and sevoflurane/fentanyl anesthesia.
Metadata last modified: 19 Dec 2024 11:32
Altmetric