Successful use of a new hand-held ECMO system in cardiopulmonary failure and bleeding shock after thrombolysis in massive post-partal pulmonary embolism

Arlt, M ; Philipp, A ; Iesalnieks, I ; Kobuch, R ; Graf, BM



Abstract

Massive pulmonary embolism (PE) leads to cardiogenic shock and is associated with mortality rates of up to 75%.(1) We report on a 27-year-old mother in childbirth who developed a massive post-partal PE and cardiac arrest. Despite mechanical resuscitation, return of spontaneous circulation (ROSC) could not be achieved. After systemic thrombolysis, ROSC returned, but cardiopulmonary failure was ...