| Veröffentlichte Version Download ( PDF | 1MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
The Efficacy and Safety of a Microwave Ablation System with a Dipole Antenna Design Featuring Floating Sleeves and Anti-Phase Technology in Stereotactic Percutaneous Liver Tumor Ablation: Results from a Prospective Study
Zhang, Liang, Luerken, Lukas, Mayr, Vinzenz, Goetz, Andrea, Schlitt, Alexandra, Stroszczynski, Christian
und Einspieler, Ingo
(2024)
The Efficacy and Safety of a Microwave Ablation System with a Dipole Antenna Design Featuring Floating Sleeves and Anti-Phase Technology in Stereotactic Percutaneous Liver Tumor Ablation: Results from a Prospective Study.
Cancers 16 (24), S. 4211.
Veröffentlichungsdatum dieses Volltextes: 21 Jan 2025 10:44
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.74725
Zusammenfassung
Purpose: To evaluate the efficacy and safety of the Surgnova Dophi™ M150E microwave ablation system in a prospective single-center observational study. Methods: A cohort of 50 patients with 77 primary or secondary liver tumors underwent CT-navigated stereotactic percutaneous microwave ablation with curative intention using the Surgnova Dophi™ M150E system. The endpoints were primary technique ...
Purpose: To evaluate the efficacy and safety of the Surgnova Dophi™ M150E microwave ablation system in a prospective single-center observational study. Methods: A cohort of 50 patients with 77 primary or secondary liver tumors underwent CT-navigated stereotactic percutaneous microwave ablation with curative intention using the Surgnova Dophi™ M150E system. The endpoints were primary technique efficacy (PTE), number of complications, ablation defect dimensions, and sphericity index compared to previously reported findings. Results: The PTE was 97.4%, with complete ablation in 75 out of 77 tumors. Complications occurred in 10% of patients, with 4% classified as major. A comparison with previous in vivo data confirmed the reliability of the system in achieving reproducible and predictable ablation results. Conclusions: Stereotactic percutaneous microwave ablation with the Surgnova Dophi™ M150E system is safe and effective for liver tumor treatment.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Cancers | ||||
| Verlag: | MDPI | ||||
|---|---|---|---|---|---|
| Band: | 16 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 24 | ||||
| Seitenbereich: | S. 4211 | ||||
| Datum | 18 Dezember 2024 | ||||
| Institutionen | Medizin > Lehrstuhl für Röntgendiagnostik | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | liver tumor; hepatocellular carcinoma; liver metastases; microwave ablation; tumor ablation; CT-guided ablation; stereotactic navigation; primary technique efficacy; interventional oncology | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Ja | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-747253 | ||||
| Dokumenten-ID | 74725 |
Downloadstatistik
Downloadstatistik