Direkt zum Inhalt

Koch, Laura ; Hahnel, Sebastian ; Rauch, Angelika ; Rosentritt, Martin

Polishing of 4Y- and 5Y- zirconia: effects on roughness, color and gloss

Koch, Laura, Hahnel, Sebastian, Rauch, Angelika und Rosentritt, Martin (2025) Polishing of 4Y- and 5Y- zirconia: effects on roughness, color and gloss. Clinical Oral Investigations 29 (3).

Veröffentlichungsdatum dieses Volltextes: 26 Feb 2025 13:11
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.75079


Zusammenfassung

Objectives To investigate the effects of polishing systems on the roughness, gloss and color of two zirconia materials as a function of the rotational speed and number of polishing movements. Materials and methods Specimens (n = 8/group) from 4Y-TZP and 5Y-TZP were milled, diamond grinded and polished. The intraoral polishing varied in the number of polishing steps, the grain size and the ...

Objectives
To investigate the effects of polishing systems on the roughness, gloss and color of two zirconia materials as a function of the rotational speed and number of polishing movements.
Materials and methods
Specimens (n = 8/group) from 4Y-TZP and 5Y-TZP were milled, diamond grinded and polished. The intraoral polishing varied in the number of polishing steps, the grain size and the matrix. Different number of polishing movements and rotation speed were used. Roughness (ISO25178-2:2021), gloss (ISO2813:2014) and color stability (ISO/CIE 11664–4:2019) were determined. Statistics: Shapiro–Wilk, one-way analysis, Bonferroni, Pearson, variance analysis/intermediate sub-effects (α = 0.05).
Results
Roughness Sa varied between 2.45 ± 0.93 µm and 6.47 ± 0.26 µm (4Y-TZP) and 2.31 ± 0.19 µm and 6.54 ± 0.22 µm (5Y-TZP). Maximum roughness Sz ranged from 32.92 ± 12.59 µm to 99.32 ± 19.87 µm (4Y-TZP) and 31.45 ± 3.02 µm to 90.75 ± 12.59 µm (5Y-TZP). Different gloss from 28.9 ± 4. 23 to 102.39 ± 18.63 GU (4Y-TZP) and 33.19 ± 3.68 to 101.28 ± 10.00 GU (5Y-TZP) was found. ΔE results ranged from 0.39 ± 0.34 to 6.30 ± 1.22 (4Y-TZP) and 0.87 ± 0.71 to 7.50 ± 1.67 (5Y-TZP). Significant (p ≥ 0.095) intermediate sub-effects were found.
Conclusions
Polishing led to a reduction in roughness, an increase in gloss and a significant change in color. Polishing had a stronger effect on 5Y-TZP.
Clinical relevance
The correct use of the polisher type (stages, binder) and its specific application (rotational speed, movements) can improve roughness, gloss and color variations.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftClinical Oral Investigations
Verlag:Springer
Band:29
Nummer des Zeitschriftenheftes oder des Kapitels:3
Datum24 Februar 2025
InstitutionenMedizin > Lehrstuhl für Zahnärztliche Prothetik
Identifikationsnummer
WertTyp
10.1007/s00784-025-06244-1DOI
Stichwörter / KeywordsZirconia · 4Y-TZP · 5V-TZP · Polishing · Roughness · Colour · Gloss
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenJa
URN der UB Regensburgurn:nbn:de:bvb:355-epub-750796
Dokumenten-ID75079

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben