Direkt zum Inhalt

Bruckschlegel, Christoph ; Fleischmann, Vivien ; Gajovic-Eichelmann, Nenad ; Wongkaew, Nongnoot

Non-enzymatic electrochemical sensors for point-of-care testing: Current status, challenges, and future prospects

Bruckschlegel, Christoph, Fleischmann, Vivien, Gajovic-Eichelmann, Nenad und Wongkaew, Nongnoot (2025) Non-enzymatic electrochemical sensors for point-of-care testing: Current status, challenges, and future prospects. Talanta 291, S. 127850.

Veröffentlichungsdatum dieses Volltextes: 11 Mrz 2025 05:56
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.75179


Zusammenfassung

Current electrochemical sensors in point-of-care (POC) testing devices rely mainly on enzyme-based sensors owing to superior sensitivity and selectivity. Nevertheless, the poor stability, high reagent cost, complex fabrication methods and requirement of specific operational conditions make their adaptability in real-world applications unfavorable. Non-enzymatic electrochemical sensors are thus ...

Current electrochemical sensors in point-of-care (POC) testing devices rely mainly on enzyme-based sensors owing to superior sensitivity and selectivity. Nevertheless, the poor stability, high reagent cost, complex fabrication methods and requirement of specific operational conditions make their adaptability in real-world applications unfavorable. Non-enzymatic electrochemical sensors are thus developed as they are more robust and cost-effective strategies. The advancement in material science and nanotechnology enables the development of novel non-enzymatic electrodes with favorable analytical performance. However, the developments are yet far from being adopted as viable products. This review therefore aims to gain insight into the field and evaluate the current progress and challenges to eventually propose future research directions. Here, fabrication strategies based on traditional and emerging technology are discussed in the light of analytical performance and cost-effectiveness. Moreover, the discussion is given on the pros and cons of non-enzymatic sensors when they are employed with various kinds of sample matrices, i.e., clinical and non-clinical samples, which must be taken into consideration for sensor development. Furthermore, molecular imprinting technology in tackling the selectivity issue is introduced and current progress is provided. Finally, the promising strategies from literature for solving the remaining challenges are included which could facilitate further development of robust POC testing devices based non-enzymatic sensors. We believe that once researchers and technology developers have reached the point where most problems are solved, the non-enzymatic sensors are going to be the robust choice for POC testing in clinical diagnostic, ensuring food safety, monitoring contaminants in environment, and bioprocess control.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftTalanta
Verlag:Elsevier
Band:291
Seitenbereich:S. 127850
Datum27 Februar 2025
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik
Projekte
Gefördert von: Deutsche Forschungsgemeinschaft (DFG) (457100614)
Identifikationsnummer
WertTyp
10.1016/j.talanta.2025.127850DOI
Stichwörter / KeywordsNon-enzymatic detection, Electrochemical sensors, Nanomaterials, Point-of-care detection, Wearable devices, Onsite detection
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
500 Naturwissenschaften und Mathematik > 570 Biowissenschaften, Biologie
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-751794
Dokumenten-ID75179

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben