Direkt zum Inhalt

Lenz, Julia Elisabeth ; Kaiser, Moritz ; Alt, Volker ; Worlicek, Michael ; von Roth, Philipp

A novel three-dimensional model for evaluation of unicompartmental knee prostheses tibial component positioning

Lenz, Julia Elisabeth , Kaiser, Moritz, Alt, Volker , Worlicek, Michael und von Roth, Philipp (2025) A novel three-dimensional model for evaluation of unicompartmental knee prostheses tibial component positioning. Archives of Orthopaedic and Trauma Surgery 145 (1).

Veröffentlichungsdatum dieses Volltextes: 07 Mai 2025 04:23
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.76645


Zusammenfassung

Background and objective This study aimed to develop an innovative method to assess the optimal positioning of the tibial component in unicompartmental knee arthroplasty. Furthermore, the authors performed a pilot study on tibial bone resections after having performed the tibial saw cuts of unicompartmental knee prostheses in 0° and 3° in the coronal plane. Materials and methods The study’s ...

Background and objective
This study aimed to develop an innovative method to assess the optimal positioning of the tibial component in unicompartmental knee arthroplasty. Furthermore, the authors performed a pilot study on tibial bone resections after having performed the tibial saw cuts of unicompartmental knee prostheses in 0° and 3° in the coronal plane.
Materials and methods
The study’s objective was achieved by devising a surface matching technique that involved comparing the tibial bone resections with three-dimensional Computer-Aided Design models of the selected tibial component. 44 bone resections of patients who had undergone unicompartmental knee arthroplasty with tibial resection angles of 0° and 3° varus in the coronal plane were evaluated in the pilot study. Furthermore, the possibility of evaluating the biological quality of the resection surface by examining the percentage of sclerotic bone in the most distal cut surface of the bony specimen was analyzed.
Results
A new method to evaluate bony resections using a three-dimensional Computer-Aided Design model could be implemented. The implementation study including 44 tibial resections following unicompartmental knee arthroplasty did not reveal significant differences between the cohorts.
Conclusion
In conclusion, we believe that the 3D modeling technique presented holds significant potential and merits application to a larger cohort of tibial bone resections for a more comprehensive investigation into the optimal tibial resection plane. Moreover, this methodology could be instrumental in the development of patient-specific implants.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftArchives of Orthopaedic and Trauma Surgery
Verlag:Springer
Band:145
Nummer des Zeitschriftenheftes oder des Kapitels:1
Datum3 Mai 2025
InstitutionenMedizin > Lehrstuhl für Unfallchirurgie
Identifikationsnummer
WertTyp
10.1007/s00402-025-05903-yDOI
Stichwörter / Keywords3D model · Unicompartmental Knee Prosthesis · Tibial Component · Positioning · Arthroplasty
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-766457
Dokumenten-ID76645

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben