Direkt zum Inhalt

Hatzipanagiotou, Maria Eleni ; Hartwig, Kathrin ; Fernandez-Pacheco, Miriam ; Plavic-Radeka, Sara ; Roth, Jonas ; Holzhauser, Ivana ; Hammer, Simone ; Ortmann, Olaf ; Seitz, Stephan

Patient acceptance and implementation of automated breast ultrasound in intensified breast cancer surveillance

Artikel

Hatzipanagiotou, Maria Eleni , Hartwig, Kathrin, Fernandez-Pacheco, Miriam , Plavic-Radeka, Sara, Roth, Jonas , Holzhauser, Ivana, Hammer, Simone, Ortmann, Olaf und Seitz, Stephan (2026) Patient acceptance and implementation of automated breast ultrasound in intensified breast cancer surveillance. Archives of Gynecology and Obstetrics 313 (1).

DOI zum Zitieren dieses Dokuments: 10.5283/epub.83179


Zusammenfassung

Purpose Automated breast ultrasound (ABUS) is a standardized ultrasound technique that may reduce operator dependency compared with hand-held ultrasound. Evidence on patient acceptance and implementation in intensified breast cancer surveillance remains limited. This study evaluated patient acceptance and clinical implementation of ABUS within a certified center of the German Consortium for ...

Purpose
Automated breast ultrasound (ABUS) is a standardized ultrasound technique that may reduce operator dependency compared with hand-held ultrasound. Evidence on patient acceptance and implementation in intensified breast cancer surveillance remains limited. This study evaluated patient acceptance and clinical implementation of ABUS within a certified center of the German Consortium for Hereditary Breast and Ovarian Cancer.
Methods
In this prospective single-center observational study, women enrolled in an intensified breast cancer surveillance program underwent ABUS examinations and completed standardized questionnaires. Patient-reported outcomes included examination-related discomfort, comparison with mammography, willingness to repeat the examination, and willingness to recommend ABUS. Workflow parameters and changes in acquisition time over repeated examinations were assessed prospectively.
Results
73 women contributed 162 ABUS examinations and corresponding questionnaires. Of these, 46/73 (63.0%) carried pathogenic variants in BRCA1, BRCA2, PALB2, or TP53, and 27/73 (37.0%) had a previous breast cancer diagnosis. Median pain score was 0 (IQR 0–1) for both breasts. Among women with previous mammography and an available comparative rating, 56/57 (98.2%) rated ABUS as more comfortable. All 73 participants (100%) were willing to undergo future ABUS examinations and recommend the procedure. Mean acquisition and interpretation times were 31.9 ± 6.2 and 9.95 ± 4.0 min, respectively. Acquisition time decreased significantly with increasing examination number (β = − 1.72 min/examination; p < 0.001).
Conclusions
ABUS was associated with high reported patient acceptance and was feasible to integrate into intensified breast cancer surveillance, with improving acquisition efficiency over time.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftArchives of Gynecology and Obstetrics
VerlagSpringer
Open Access ArtDEAL (Springer Gold)
Band313
Nummer des Zeitschriftenheftes oder des Kapitels1
Datum13 November 2026
Veröffentlichungsdatum17 Nov 2026 07:42
InstitutionenMedizin > Lehrstuhl für Frauenheilkunde und Geburtshilfe (Schwerpunkt Frauenheilkunde)
Medizin > Lehrstuhl für Humangenetik
Medizin > Lehrstuhl für Röntgendiagnostik
Identifikationsnummer
WertTyp
10.1007/s00404-026-08603-zDOI
Stichwörter / KeywordsAutomated breast ultrasound · Intensified breast cancer surveillance · Surveillance program · ABUS · German Consortium for Hereditary Breast and Ovarian Cancer
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-831796
Dokumenten-ID83179

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben