| Veröffentlichte Version Download ( PDF | 2MB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Comparative evaluation of handheld vs. high-end ultrasound systems for TIPSS hemodynamic assessment: first impressions
Artikel
Dropco, Ivor
, Vehling-Kaiser, Ursula, Kaiser, Florian, Kaiser, Eleène, Thurn, Sylvia, Kück, Fabian, Herr, Wolfgang, Schlitt, Hans Jürgen, Stroszczynski, Christian
, Jung, Ernst Michael und Kaiser, Ulrich
(2026)
Comparative evaluation of handheld vs. high-end ultrasound systems for TIPSS hemodynamic assessment: first impressions.
BMC Medical Imaging 26 (1).
DOI zum Zitieren dieses Dokuments: 10.5283/epub.81161
Zusammenfassung
Background Transjugular intrahepatic portosystemic shunt (TIPSS) procedures require reliable post-interventional hemodynamic monitoring to detect shunt dysfunction, for which Doppler ultrasonography is the preferred modality. Owing to the rapid development of handheld ultrasound devices, their diagnostic equivalence to high-end systems warrants investigation. Materials and methods A pilot ...
Background
Transjugular intrahepatic portosystemic shunt (TIPSS) procedures require reliable post-interventional hemodynamic monitoring to detect shunt dysfunction, for which Doppler ultrasonography is the preferred modality. Owing to the rapid development of handheld ultrasound devices, their diagnostic equivalence to high-end systems warrants investigation.
Materials and methods
A pilot group of 23 patients (n = 13 males, 65%; n = 7 females; 35%; n = 3 unknown) with intrahepatic TIPSS were retrospectively analyzed. Blood flow measurements were obtained and compared using a high-end ultrasound system (Resona R9, Mindray) and modern handheld ultrasound device (Vscan Air™ CL, GE). The TIPSS was evaluated using B-mode and color Doppler sonography. Image quality was assessed using a 5-point scale and flow parameters using statistical analysis. The image quality and the difference between the two devices were analyzed using correlation coefficients and multivariable linear regression models including TIPSS flow values, skin-to-TIPSS distance, and TIPSS dwell time.
Results
Both devices produced clinically interpretable images. However, the high-end device yielded superior image quality in 16 of 23 cases (p < 0.001). Significant correlations were observed between the difference in mean TIPSS flow measurements obtained by the two devices (Δ mean TIPSS flow) and corresponding average flow values measured by the two devices (Kendall’s τ = 0.656; p < 0.001). Significant associations with Δ TIPSS mean flow were identified for skin-to-TIPSS distance (τ = 0.39; p = 0.014) and TIPSS dwell time (τ = −0.39; p = 0.017). In multivariable analysis, both mean TIPSS flow measured by the high-end system and skin-to-TIPSS distance remained significantly associated with Δ TIPSS mean flow. The TIPSS mean flow measured by the high-end system correlated with TIPSS dwell time (τ = 0.38; p = 0.021). Bland–Altman analysis revealed that handheld measurements tended to overestimate low flows and underestimate high flows.
Conclusion
Handheld ultrasound devices show promising potential for TIPSS surveillance; however, they could lead to distorted flow deviations. Contemporary handheld devices may nevertheless be useful in selected point-of-care settings but cannot yet replace high-end systems for precise hemodynamic monitoring. Larger prospective studies are required.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | BMC Medical Imaging | ||||
| Verlag | Springer | ||||
| Open Access Art | DEAL (Springer Gold) | ||||
| Band | 26 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels | 1 | ||||
| Datum | 11 November 2026 | ||||
| Veröffentlichungsdatum | 17 Nov 2026 05:52 | ||||
| Institutionen | Medizin > Lehrstuhl für Chirurgie Medizin > Lehrstuhl für Innere Medizin III (Hämatologie und Internistische Onkologie) Medizin > Lehrstuhl für Röntgendiagnostik | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | TIPSS, Ultrasound, Handheld ultrasound, Liver perfusion, Duplex Sonography | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Zum Teil | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-811616 | ||||
| Dokumenten-ID | 81161 |