Direkt zum Inhalt

Liebl, B. ; Haen, Ekkehard ; Romacker, U. ; Nguyen, P. T. ; Remien, J.

The use of robots and computers in the organisation of studies on the circadian variation of beta 2-adrenoceptor sites in peripheral mononuclear leucocytes

Liebl, B., Haen, Ekkehard, Romacker, U., Nguyen, P. T. und Remien, J. (1990) The use of robots and computers in the organisation of studies on the circadian variation of beta 2-adrenoceptor sites in peripheral mononuclear leucocytes. Chronobiology international 7 (3), S. 235-238.

Veröffentlichungsdatum dieses Volltextes: 20 Apr 2011 08:47
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.19639


Zusammenfassung

We have developed a partially automated method for the performance of equilibrium radioligand binding studies which is applied by our group in investigations on circadian variations and stimulation studies on beta 2-adrenoceptor sites in human peripheral mononuclear leucocytes (pMNL). Using a Tecan Robotic Sample Processor, binding assays with 12 concentrations of 125iodocyanopindolol (1-150 ...

We have developed a partially automated method for the performance of equilibrium radioligand binding studies which is applied by our group in investigations on circadian variations and stimulation studies on beta 2-adrenoceptor sites in human peripheral mononuclear leucocytes (pMNL). Using a Tecan Robotic Sample Processor, binding assays with 12 concentrations of 125iodocyanopindolol (1-150 pmol/l, total binding in triplicates, unspecific binding in the presence of 10(-5) mol/l timolol in duplicates) are prepared automatically with all titer tubes per experiment arranged in a microtiterplate-sized rack. After incubation in a waterbath for 2hr at 37 degrees C, the whole rack is centrifuged at 5000g and transferred back to the lab robot. Bound radioactivity is separated from the unbound ligand by removing the supernatant by the machine. The radioactive counts are evaluated using personal computers. The lab robot enhances reproducibility of experimental results and frees lab workers from time-consuming pipetting jobs. Radioactive exposure is minimized to the time preparing the radioligand working solution and transferring the sample tubes from the robot to the waterbath, to the centrifuge and back to the robot. The variability of our software allows easy adaptation to other binding studies with intact cells.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftChronobiology international
Verlag:Pergamon Press; Taylor & Francis
Band:7
Nummer des Zeitschriftenheftes oder des Kapitels:3
Seitenbereich:S. 235-238
Datum1990
InstitutionenMedizin > Lehrstuhl für Psychiatrie und Psychotherapie
Identifikationsnummer
WertTyp
2176573PubMed-ID
Klassifikation
NotationArt
Circadian Rhythm/physiologyMESH
ComputersMESH
HumansMESH
Leukocytes, Mononuclear/metabolismMESH
Radioligand Assay/instrumentationMESH
Receptors, Adrenergic, beta/bloodMESH
RoboticsMESH
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetUnbekannt / Keine Angabe
An der Universität Regensburg entstandenUnbekannt / Keine Angabe
URN der UB Regensburgurn:nbn:de:bvb:355-epub-196392
Dokumenten-ID19639

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben