Baleizo, Carlos ; Nagl, Stefan ; Schäferling, Michael ; Berberan-Santos, Mario S. ; Wolfbeis, Otto S.

Dual Fluorescence Sensor for Trace Oxygen and Temperature with Unmatched Range and Sensitivity

Baleizo, Carlos , Nagl, Stefan , Schäferling, Michael, Berberan-Santos, Mario S. und Wolfbeis, Otto S. (2008) Dual Fluorescence Sensor for Trace Oxygen and Temperature with Unmatched Range and Sensitivity. Analytical Chemistry (including News & Features) 80 (16), S. 6449-6457.

Veröffentlichungsdatum dieses Volltextes: 18 Mrz 2011 07:36
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.20089


Zusammenfassung

An optical dual sensor for oxygen and temperature is presented that is highly oxygen sensitive and covers a broad temperature range. Dual sensing is based on luminescence lifetime measurements. The novel sensor contains two luminescent compounds incorporated into polymer films. The temperature-sensitive dye (ruthenium tris-1,10-phenanthroline) has a highly temperature-dependent luminescence and ...

An optical dual sensor for oxygen and temperature is presented that is highly oxygen sensitive and covers a broad temperature range. Dual sensing is based on luminescence lifetime measurements. The novel sensor contains two luminescent compounds incorporated into polymer films. The temperature-sensitive dye (ruthenium tris-1,10-phenanthroline) has a highly temperature-dependent luminescence and is incorporated in poly(acrylonitrile) to avoid cross-sensitivity to oxygen. Fullerene C-70 was used as the oxygen-sensitive probe owing to its strong thermally activated delayed fluorescence at elevated temperatures that is extremely oxygen sensitive. The cross-sensitivity of C-70 to temperature is accounted for by means of the temperature sensor. C-70 is incorporated into a highly oxygen-permeable polymer, either ethyl cellulose or organosilica. The two luminescent probes have different emission spectra and decay times, and their emissions can be discriminated using both parameters. Spatially resolved sensing is achieved by means of fluorescence lifetime imaging. The response times of the sensor to oxygen are short. The dual sensor exhibits a temperature operation range between at least 0 and 120 degrees C, and detection limits for oxygen in the ppbv range, operating for oxygen concentrations up to at least 50 ppmv. These ranges outperform all dual oxygen and temperature sensors reported so far. The dual sensor presented in this study is especially appropriate for, measurements under extreme conditions such as high temperatures and ultralow oxygen levels. This dual sensor is a key step forward in a number of scientifically or commercially important applications including food packaging, for monitoring of hyperthermophilic microorganisms, in space technology, and safety and security applications in terms of detection of oxygen leaks.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftAnalytical Chemistry (including News & Features)
Verlag:AMER CHEMICAL SOC
Ort der Veröffentlichung:WASHINGTON
Band:80
Nummer des Zeitschriftenheftes oder des Kapitels:16
Seitenbereich:S. 6449-6457
Datum24 Juli 2008
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, ehemals Prof. Wolfbeis)
Identifikationsnummer
WertTyp
10.1021/ac801034pDOI
Stichwörter / KeywordsACTIVATED DELAYED FLUORESCENCE; LOWEST TRIPLET-STATE; CARBON-DIOXIDE; CHEMICAL SENSORS; DISSOLVED-OXYGEN; LIQUID SOLUTION; C-70; PRESSURE; PHOSPHORESCENCE; PROBES;
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
StatusVeröffentlicht
BegutachtetUnbekannt / Keine Angabe
An der Universität Regensburg entstandenUnbekannt / Keine Angabe