Zusammenfassung

A method for the fluorescent imaging of glucose is described that is based on the detection of enzymatically produced hydrogen peroxide, using the europium(III) tetracycline complex as the fluorescent probe incorporated into a hydrophilic polymer layer. Coadsorption of glucose oxidase (GOx) makes these sensor layers respond to the hydrogen peroxide produced by the GOx-assisted oxidation of ...

A method for the fluorescent imaging of glucose is described that is based on the detection of enzymatically produced hydrogen peroxide, using the europium(III) tetracycline complex as the fluorescent probe incorporated into a hydrophilic polymer layer. Coadsorption of glucose oxidase (GOx) makes these sensor layers respond to the hydrogen peroxide produced by the GOx-assisted oxidation of glucose. The hydrogel layers are integrated into a 96-microwell plate for a parallel and simultaneous detection of various samples. Glucose is visualized by means of time resolved luminescence lifetime imaging. Unlike in previous methods, the determination of H2O2 does not require the addition of peroxidase or a catalyst to form a fluorescent product. The lifetime-based images obtained are compared with conventional fluorescence intensity-based methods with respect to sensitivity and the dynamic range of the sensor layer. The main advantages provided by this sensing scheme for H2O2 include reversibility, applicability at neutral pH, and the straightforwardness of the transducer system and the imaging device.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftJournal of Fluorescence
Verlag:KLUWER ACADEMIC/PLENUM PUBL
Ort der Veröffentlichung:NEW YORK
Band:14
Nummer des Zeitschriftenheftes oder des Kapitels:5
Seitenbereich:S. 561-568
Datum2004
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik > Chemo- und Biosensorik (Prof. Antje J. Bäumner, ehemals Prof. Wolfbeis)
Identifikationsnummer
WertTyp
10.1023/B:JOFL.0000039343.02843.12DOI
Stichwörter / KeywordsHYDROGEN-PEROXIDE; OPTICAL SENSORS; ENERGY-TRANSFER; OXYGEN SENSORS; IN-VIVO; BIOSENSOR; PROBE; PH; OPTRODE; IMAGES; optical sensor; time-resolved fluorescence imaging; europium tetracycline; glucose sensor
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
StatusVeröffentlicht
BegutachtetUnbekannt / Keine Angabe
An der Universität Regensburg entstandenUnbekannt / Keine Angabe
Dokumenten-ID20460

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben