Analysis of velocity sedimentation techniques in cell separation. Influence of apparative and sample properties on separative power, resolution and sensitivity
Zeiller, K., Hansen, Ernil, Leihener, D., Pascher, G. and Wirth, H. (1976) Analysis of velocity sedimentation techniques in cell separation. Influence of apparative and sample properties on separative power, resolution and sensitivity. Hoppe-Seyler's Zeitschrift für physiologische Chemie 357 (9), pp. 1309-1319.Date of publication of this fulltext: 05 Sep 2011 13:29
Article
DOI to cite this document: 10.5283/epub.22000
Abstract
In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be ...
In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be improved. On the other hand an apparative modification is presented which improves the separation power and makes sample loading independent of the gradient filling. If cells (from rat bone marrow) were separated, a several times higher dispersion for a given cell volume was observed than was due to the apparative error. It was concluded that density variations were the major source of this dispersion. Since cell volume and density apparently show independent variations within a biological cell population the cell density cannot be disregarded if velocity sedimentation profiles are discussed in physical terms as is often done.
Alternative links to fulltext
Involved Institutions
Details
| Item type | Article | ||||||||||||||
| Journal or Publication Title | Hoppe-Seyler's Zeitschrift für physiologische Chemie | ||||||||||||||
| Publisher: | de Gruyter | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Volume: | 357 | ||||||||||||||
| Number of Issue or Book Chapter: | 9 | ||||||||||||||
| Page Range: | pp. 1309-1319 | ||||||||||||||
| Date | 1976 | ||||||||||||||
| Institutions | Medicine > Lehrstuhl für Anästhesiologie | ||||||||||||||
| Identification Number |
| ||||||||||||||
| Classification |
| ||||||||||||||
| Dewey Decimal Classification | 600 Technology > 610 Medical sciences Medicine | ||||||||||||||
| Status | Published | ||||||||||||||
| Refereed | Yes, this version has been refereed | ||||||||||||||
| Created at the University of Regensburg | Unknown | ||||||||||||||
| URN of the UB Regensburg | urn:nbn:de:bvb:355-epub-220001 | ||||||||||||||
| Item ID | 22000 |