Direkt zum Inhalt

Zeiller, K. ; Hansen, Ernil ; Leihener, D. ; Pascher, G. ; Wirth, H.

Analysis of velocity sedimentation techniques in cell separation. Influence of apparative and sample properties on separative power, resolution and sensitivity

Zeiller, K., Hansen, Ernil, Leihener, D., Pascher, G. und Wirth, H. (1976) Analysis of velocity sedimentation techniques in cell separation. Influence of apparative and sample properties on separative power, resolution and sensitivity. Hoppe-Seyler's Zeitschrift für physiologische Chemie 357 (9), S. 1309-1319.

Veröffentlichungsdatum dieses Volltextes: 05 Sep 2011 13:29
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.22000


Zusammenfassung

In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be ...

In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be improved. On the other hand an apparative modification is presented which improves the separation power and makes sample loading independent of the gradient filling. If cells (from rat bone marrow) were separated, a several times higher dispersion for a given cell volume was observed than was due to the apparative error. It was concluded that density variations were the major source of this dispersion. Since cell volume and density apparently show independent variations within a biological cell population the cell density cannot be disregarded if velocity sedimentation profiles are discussed in physical terms as is often done.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftHoppe-Seyler's Zeitschrift für physiologische Chemie
Verlag:de Gruyter
Band:357
Nummer des Zeitschriftenheftes oder des Kapitels:9
Seitenbereich:S. 1309-1319
Datum1976
InstitutionenMedizin > Lehrstuhl für Anästhesiologie
Identifikationsnummer
WertTyp
992581PubMed-ID
Klassifikation
NotationArt
Cell Separation/methodsMESH
DensitometryMESH
KineticsMESH
MathematicsMESH
Particle SizeMESH
ViscosityMESH
Dewey-Dezimal-Klassifikation600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenUnbekannt / Keine Angabe
URN der UB Regensburgurn:nbn:de:bvb:355-epub-220001
Dokumenten-ID22000

Bibliographische Daten exportieren