Zeiller, K., Hansen, Ernil, Leihener, D., Pascher, G. and Wirth, H. (1976) Analysis of velocity sedimentation techniques in cell separation. Influence of apparative and sample properties on separative power, resolution and sensitivity. Hoppe-Seyler's Zeitschrift für physiologische Chemie 357 (9), pp. 1309-1319.

Date of publication of this fulltext: 05 Sep 2011 13:29
Article
DOI to cite this document: 10.5283/epub.22000


Abstract

In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be ...

In the present investigation the velocity sedimentation technique was analysed with respect to separation resolution, power and sensitivity. It was found that apparative modifications do not influence the resolution, which is a function of the contribution of apparative errors to the dispersion. A surprisingly small parameter of 0.15 was determined and it seems unlikely that this value can be improved. On the other hand an apparative modification is presented which improves the separation power and makes sample loading independent of the gradient filling. If cells (from rat bone marrow) were separated, a several times higher dispersion for a given cell volume was observed than was due to the apparative error. It was concluded that density variations were the major source of this dispersion. Since cell volume and density apparently show independent variations within a biological cell population the cell density cannot be disregarded if velocity sedimentation profiles are discussed in physical terms as is often done.



Involved Institutions


Details

Item typeArticle
Journal or Publication TitleHoppe-Seyler's Zeitschrift für physiologische Chemie
Publisher:de Gruyter
Volume:357
Number of Issue or Book Chapter:9
Page Range:pp. 1309-1319
Date1976
InstitutionsMedicine > Lehrstuhl für Anästhesiologie
Identification Number
ValueType
992581PubMed ID
Classification
NotationType
Cell Separation/methodsMESH
DensitometryMESH
KineticsMESH
MathematicsMESH
Particle SizeMESH
ViscosityMESH
Dewey Decimal Classification600 Technology > 610 Medical sciences Medicine
StatusPublished
RefereedYes, this version has been refereed
Created at the University of RegensburgUnknown
URN of the UB Regensburgurn:nbn:de:bvb:355-epub-220001
Item ID22000

Export bibliographical data

Owner only: item control page

nach oben