Dokumentenart: | Artikel | ||||
---|---|---|---|---|---|
Titel eines Journals oder einer Zeitschrift: | The American Journal of Cardiology | ||||
Verlag: | EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC | ||||
Ort der Veröffentlichung: | BRIDGEWATER | ||||
Band: | 118 | ||||
Nummer des Zeitschriftenheftes oder des Kapitels: | 1 | ||||
Seitenbereich: | S. 86-94 | ||||
Datum: | 2016 | ||||
Institutionen: | Medizin > Lehrstuhl für Innere Medizin II | ||||
Identifikationsnummer: |
| ||||
Stichwörter / Keywords: | ACUTE MYOCARDIAL-INFARCTION; SUDDEN CARDIAC DEATH; HEART-RATE; VENTRICULAR-ARRHYTHMIAS; RISK STRATIFICATION; NATRIURETIC PEPTIDE; CLINICAL-USE; MADIT-II; MORTALITY; TRIAL; | ||||
Dewey-Dezimal-Klassifikation: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
Status: | Veröffentlicht | ||||
Begutachtet: | Ja, diese Version wurde begutachtet | ||||
An der Universität Regensburg entstanden: | Ja | ||||
Dokumenten-ID: | 42653 |
Zusammenfassung
In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holier variables in a population who underwent ...
Zusammenfassung
In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holier variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holler for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 +/- 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (>= 1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks (clinicaltrials.gov: NCT02010515). (C) 2016 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY NC -ND license (http://creativecommons.orgflicenses/by-nc-nd/4.00. (Am J Cardiol 2016;118:86-94)
Metadaten zuletzt geändert: 17 Mrz 2020 11:34