| Eingereichte Version Download ( PDF | 350kB) | Lizenz: Creative Commons Namensnennung 4.0 International |
Short-Term Tinnitus Suppression With Electric-Field Guided rTMS for Individualizing rTMS Treatment: A Technical Feasibility Report
Schoisswohl, Stefan
, Langguth, Berthold und Schecklmann, Martin
(2020)
Short-Term Tinnitus Suppression With Electric-Field Guided rTMS for Individualizing rTMS Treatment: A Technical Feasibility Report.
Frontiers in Neurology 11 (86), S. 1-5.
Veröffentlichungsdatum dieses Volltextes: 26 Mrz 2020 14:44
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.43032
Zusammenfassung
Background: Past research highlighted the benefits of personalized repetitive transcranial magnetic stimulation (rTMS) for the treatment of chronic subjective tinnitus. Objective/Hypothesis: The objective was to investigate the feasibility of rTMS personalization by identifying individually optimal stimulation parameters in test sessions. Particularly, effectiveness and retest-reliability of ...
Background: Past research highlighted the benefits of personalized repetitive transcranial magnetic stimulation (rTMS) for the treatment of chronic subjective tinnitus. Objective/Hypothesis: The objective was to investigate the feasibility of rTMS personalization by identifying individually optimal stimulation parameters in test sessions. Particularly, effectiveness and retest-reliability of different stimulation parameters were examined. Methods: Via electric-field guided rTMS, five patients were stimulated with different frequencies on three positions of the left and right superior temporal gyrus on 2 separate days. After each stimulation, the patients had to evaluate tinnitus loudness and discomfort of the used protocol. Results: Individualization of rTMS was possible in all five patients. Significant lower tinnitus loudness was found for 1 Hz stimulation. Positive correlations between 2 days were observed for hemisphere (left, right), position (mSTG, pSTG), and frequency (1, 10, 20 Hz). High-frequency stimulation produced high discomfort. Conclusion: Personalization of rTMS is considered as feasible. Consistency of parameter-specific tinnitus suppression is demonstrated.
Alternative Links zum Volltext
Beteiligte Einrichtungen
Details
| Dokumentenart | Artikel | ||||
| Titel eines Journals oder einer Zeitschrift | Frontiers in Neurology | ||||
| Verlag: | Frontiers | ||||
|---|---|---|---|---|---|
| Ort der Veröffentlichung: | LAUSANNE | ||||
| Band: | 11 | ||||
| Nummer des Zeitschriftenheftes oder des Kapitels: | 86 | ||||
| Seitenbereich: | S. 1-5 | ||||
| Datum | 25 Februar 2020 | ||||
| Institutionen | Medizin > Lehrstuhl für Psychiatrie und Psychotherapie | ||||
| Identifikationsnummer |
| ||||
| Stichwörter / Keywords | TRANSCRANIAL MAGNETIC STIMULATION; repetitive transcranial magnetic stimulation; tinnitus; neuronavigation; individualized treatment; personalized medicine | ||||
| Dewey-Dezimal-Klassifikation | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
| Status | Veröffentlicht | ||||
| Begutachtet | Ja, diese Version wurde begutachtet | ||||
| An der Universität Regensburg entstanden | Ja | ||||
| URN der UB Regensburg | urn:nbn:de:bvb:355-epub-430329 | ||||
| Dokumenten-ID | 43032 |