Titel eines Journals oder einer Zeitschrift: | Clinical Hemorheology and Microcirculation | ||||
Verlag: | IOS PRESS | ||||
Ort der Veröffentlichung: | AMSTERDAM | ||||
Band: | 71 | ||||
Nummer des Zeitschriftenheftes oder des Kapitels: | 2 | ||||
Seitenbereich: | S. 267-276 | ||||
Datum: | 2019 | ||||
Institutionen: | Medizin > Lehrstuhl für Innere Medizin III (Hämatologie und Internistische Onkologie) Medizin > Abteilung für Nephrologie Medizin > Lehrstuhl für Röntgendiagnostik Medizin > Lehrstuhl für Strahlentherapie | ||||
Identifikationsnummer: |
| ||||
Stichwörter / Keywords: | ULTRASOUND CEUS; RADIOFREQUENCY ABLATION; DIAGNOSTIC-ACCURACY; ARTERIAL PHASE; PATTERNS; MASSES; CT; MEDIA; MRI; CEUS; liver imaging; interdisciplinary ultrasound department; examination conditions; tumor | ||||
Dewey-Dezimal-Klassifikation: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
Status: | Veröffentlicht | ||||
Begutachtet: | Ja, diese Version wurde begutachtet | ||||
An der Universität Regensburg entstanden: | Ja | ||||
Dokumenten-ID: | 49144 |
Zusammenfassung
AIM: To assess the influence of difficult examination conditions onto the diagnostic performance of CEUS (contrast-enhanced ultrasound) in focal liver lesions (FLL). METHODS: 77 liver CEUS examinations of 75 patients were analysed retrospectively. CEUS was performed as the first diagnostic procedure by one experienced sonographer after bolus injection of 1.0 up to 2.4 ml sulphur hexafluoride ...
Zusammenfassung
AIM: To assess the influence of difficult examination conditions onto the diagnostic performance of CEUS (contrast-enhanced ultrasound) in focal liver lesions (FLL). METHODS: 77 liver CEUS examinations of 75 patients were analysed retrospectively. CEUS was performed as the first diagnostic procedure by one experienced sonographer after bolus injection of 1.0 up to 2.4 ml sulphur hexafluoride microbubbles using a high-end ultrasound device with a high resolution multifrequency probe (1-6 MHz). The combination of complementary imaging (CT or MRI), histology and CEUS follow up of at least 6 months was considered. Cross tables were used to define the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy. Chi-Square Test analysed categorical data. RESULTS: The patients were between 18 and 84 years old (mean 62 +/- 11 years). 26 patients suffered from liver cirrhosis (33.8%). 52 patients (67.5%) received therapy for an oncological disease. The final diagnosis showed 52 malignant FLLs including 24 hepatocellular carcinomas (HCCs), 9 cholangiocellular carcinomas (CCCs) and 19 metastases from different primary tumors. In the other 25 patients no malignant lesions could be detected, three of them presenting however liver haemangioma and two of them liver cysts. The overall lesions' size according to the CEUS findings ranged from 7 to 100 mm (mean 31.1 +/- 2.6 mm). Under good examination conditions the malignant potential of a tumor was diagnosed correctly by CEUS in 98.0% of cases (Sensitivity 97.1%, Specificity 100%, PPV 100%, NPV 94.1%, diagnostic accuracy 98.0%). Limited examination conditions (e.g. obesity, meteorism) were present in 35.1% of cases with a decrease of the diagnostic accuracy to 92.6% (Sensitivity 100%, Specificity 77.8%, PPV 90.0%, NPV 100%). CONCLUSION: Despite the influence of difficult examination conditions, CEUS is - in the hands of an experienced sonographer - an excellent diagnostic procedure for the assessment of liver lesions.