Dokumentenart: | Artikel | ||||
---|---|---|---|---|---|
Titel eines Journals oder einer Zeitschrift: | RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren | ||||
Verlag: | GEORG THIEME VERLAG KG | ||||
Ort der Veröffentlichung: | STUTTGART | ||||
Band: | 193 | ||||
Nummer des Zeitschriftenheftes oder des Kapitels: | 04 | ||||
Seitenbereich: | S. 446-458 | ||||
Datum: | 2021 | ||||
Institutionen: | Medizin > Lehrstuhl für Röntgendiagnostik Medizin > Zentren des Universitätsklinikums Regensburg > Zentrum für Klinische Studien | ||||
Identifikationsnummer: |
| ||||
Stichwörter / Keywords: | MAGNETIC-RESONANCE ANGIOGRAPHY; DISTINGUISHING HIGH-FLOW; ANOMALIES HEMANGIOMAS; CLASSIFICATION; SCLEROTHERAPY; OUTCOMES; peripheral vascular malformation; magnetic resonance imaging (MRI); short tau inversion recovery (STIR); volume interpolated breath-hold examination (VIBE); 3; 0 Tesla; morphologic characteristics | ||||
Dewey-Dezimal-Klassifikation: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
Status: | Veröffentlicht | ||||
Begutachtet: | Ja, diese Version wurde begutachtet | ||||
An der Universität Regensburg entstanden: | Ja | ||||
Dokumenten-ID: | 50631 |
Zusammenfassung
Purpose To assess morphological and hemodynamic characteristics of peripheral vascular malformations on 3 T magnetic resonance imaging (MRI) including qualitative comparison of two fat-saturated sequences: short tau inversion recovery (STIR) and three-dimensional high-resolution volume interpolated gradient recalled echo (GRE). Materials and Methods During 9 months, 100 patients with suspected or ...
Zusammenfassung
Purpose To assess morphological and hemodynamic characteristics of peripheral vascular malformations on 3 T magnetic resonance imaging (MRI) including qualitative comparison of two fat-saturated sequences: short tau inversion recovery (STIR) and three-dimensional high-resolution volume interpolated gradient recalled echo (GRE). Materials and Methods During 9 months, 100 patients with suspected or known vascular malformations were prospectively assessed on a 3 T scanner using T2-weighted STIR and turbo spin echo (TSE), T1-weighted TSE, time-resolved contrast-enhanced magnetic resonance angiography (MRA) with interleaved stochastic trajectories (TWIST) and T1-weighted volume interpolated breath-hold examination (VIBE) after contrast enhancement. The analysis included signal behavior and morphologic and hemodynamic characteristics. Additionally, the image quality of the fat-saturated sequences was evaluated by 2 radiologists. Results 86 patients (14 dropouts; 57 female, 29 male; mean age 26.8 years, age range 1-56) were analyzed. 22 had high-flow and 64 low-flow malformations, including 14 with a lymphatic component. In 21 of 22 patients with high-flow malformations, typical characteristics (flow voids, hyperdynamic arteriovenous fistula, dilated main/feeder-arteries and draining veins) were documented. Patients with low-flow malformations had phleboliths in 35 cases, fluid-fluid levels in 47 and dilated draining veins in 23. Lymphatic malformations showed peripheral contrast enhancement of cyst walls in the volume interpolated GRE. The comparison of fat-saturated sequences showed significantly better results of the volume interpolated GRE in all categories except the presence of artifacts which were significantly reduced in the STIR (p < 0.05). Conclusion 3 T MRI with MRA provides detailed morphological and hemodynamic information of different types of peripheral vascular malformations. Contrast-enhanced high-resolution volume interpolated GRE proved superior to STIR in differentiating morphologic features and to be diagnostic in the differentiation of lymphatic parts and joint involvement. Citation Format Hohn F, Hammer S, Fellner C et al. 3T MRI of Peripheral Vascular Malformations: Characteristics and Comparison of Two Fat-Saturated sequences: Short Tau Inversion Recovery Versus Three-Dimensional High-Resolution Volume Interpolated Gradient Recalled Echo. Fortschr Rontgenstr 2020; DOI: 10.1055/a-1253-8422
Metadaten zuletzt geändert: 11 Okt 2021 13:10