Direkt zum Inhalt

Khairy, Gasser M. ; Abd El-Naby, Zaitona A. ; Elgindy, Alaa M. A. ; Duerkop, Axel ; Abdel Hameed, Eman A.

Sensitive Determination of Moxifloxacin HCl in Pharmaceuticals or Human Plasma Using Luminescence or Eye Vision

Khairy, Gasser M. , Abd El-Naby, Zaitona A., Elgindy, Alaa M. A., Duerkop, Axel und Abdel Hameed, Eman A. (2022) Sensitive Determination of Moxifloxacin HCl in Pharmaceuticals or Human Plasma Using Luminescence or Eye Vision. Chemosensors 10 (10), S. 378.

Veröffentlichungsdatum dieses Volltextes: 29 Sep 2022 08:23
Artikel
DOI zum Zitieren dieses Dokuments: 10.5283/epub.52941


Zusammenfassung

A new probe based on the complex of 1,2 dihydro-2-oxoquinoloine-4-carboxylic acid (DOCA) as a ligand with Europium (III) ion was developed for the quantitation of Moxifloxacin HCl (Moxi.HCl) in pharmaceuticals and human plasma using a luminescence method. The metal to ligand ratio of the complex is 1:2 as determined by a Job plot. The determination of Moxi.HCl is based on static quenching of the ...

A new probe based on the complex of 1,2 dihydro-2-oxoquinoloine-4-carboxylic acid (DOCA) as a ligand with Europium (III) ion was developed for the quantitation of Moxifloxacin HCl (Moxi.HCl) in pharmaceuticals and human plasma using a luminescence method. The metal to ligand ratio of the complex is 1:2 as determined by a Job plot. The determination of Moxi.HCl is based on static quenching of the luminescence of the probe upon coordination of Moxi.HCl. The negative value for Delta G proves that this reaction is spontaneous. The calibration curve was constructed based on a Stern-Volmer equation and the quantitation range was 0.05-80 mu g mL(-1). This is low enough to determine the drug in blood plasma, even hours after administration, which is not feasible with the methods published so far. The LOD was 15 ng mL(-1). The accuracy of the method was demonstrated by good recoveries of spiking experiments in tablets, ophthalmic eyedrops and human blood plasma, where the mean recovery was 99% with RSDs below 5%. The method was validated by closely matching concentrations of the drug found in all these real samples by HPLC. Additionally, Moxi.HCl can be assessed semi-quantitatively by eye vision upon excitation with a UV lamp at 365 nm by a gradual color shift from red to blue with increasing concentrations of Moxi.HCl.



Beteiligte Einrichtungen


Details

DokumentenartArtikel
Titel eines Journals oder einer ZeitschriftChemosensors
Verlag:MDPI
Ort der Veröffentlichung:BASEL
Band:10
Nummer des Zeitschriftenheftes oder des Kapitels:10
Seitenbereich:S. 378
Datum21 September 2022
InstitutionenChemie und Pharmazie > Institut für Analytische Chemie, Chemo- und Biosensorik
Identifikationsnummer
WertTyp
10.3390/chemosensors10100378DOI
Stichwörter / KeywordsATOMIC-ABSORPTION; VALIDATION; SOLVATOCHROMISM; GATIFLOXACIN; ANTIBIOTICS; EFFICACY; PROBES; probes; lanthanide complexes; moxifloxacin HCl; luminescence; fluorescence; HPLC
Dewey-Dezimal-Klassifikation500 Naturwissenschaften und Mathematik > 540 Chemie
500 Naturwissenschaften und Mathematik > 570 Biowissenschaften, Biologie
StatusVeröffentlicht
BegutachtetJa, diese Version wurde begutachtet
An der Universität Regensburg entstandenZum Teil
URN der UB Regensburgurn:nbn:de:bvb:355-epub-529417
Dokumenten-ID52941

Bibliographische Daten exportieren

Nur für Besitzer und Autoren: Kontrollseite des Eintrags

nach oben