Dokumentenart: | Artikel | ||||
---|---|---|---|---|---|
Titel eines Journals oder einer Zeitschrift: | Clinical Breast Cancer | ||||
Verlag: | CIG MEDIA GROUP, LP | ||||
Ort der Veröffentlichung: | DALLAS | ||||
Band: | 22 | ||||
Nummer des Zeitschriftenheftes oder des Kapitels: | 2 | ||||
Seitenbereich: | e142-e146 | ||||
Datum: | 2022 | ||||
Institutionen: | Medizin > Lehrstuhl für Frauenheilkunde und Geburtshilfe (Schwerpunkt Frauenheilkunde) | ||||
Identifikationsnummer: |
| ||||
Stichwörter / Keywords: | CLINICAL EXAMINATION; TUMOR RESPONSE; MAMMOGRAPHY; ACCURACY; CHEMOTHERAPY; MRI; ULTRASONOGRAPHY; SONOGRAPHY; Automatic breast ultrasound; Neoadjuvant chemotherapy; Response control; Breast cancer; Imaging modalities | ||||
Dewey-Dezimal-Klassifikation: | 600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin | ||||
Status: | Veröffentlicht | ||||
Begutachtet: | Ja, diese Version wurde begutachtet | ||||
An der Universität Regensburg entstanden: | Ja | ||||
Dokumenten-ID: | 57052 |
Zusammenfassung
This study evaluated the use of Automated Breast Ultrasound Screening (ABUS) for response control in neoadjuvant chemotherapy. Response controls via ABUS and handheld ultrasound were compared with pathologic tumor size. There was no statistical difference between the measurements with handheld ultrasound or ABUS. ABUS seems to be a suitable method to conduct response control in neoadjuvant breast ...
Zusammenfassung
This study evaluated the use of Automated Breast Ultrasound Screening (ABUS) for response control in neoadjuvant chemotherapy. Response controls via ABUS and handheld ultrasound were compared with pathologic tumor size. There was no statistical difference between the measurements with handheld ultrasound or ABUS. ABUS seems to be a suitable method to conduct response control in neoadjuvant breast cancer treatment. Introduction: The Invenia Automated Breast Ultrasound Screening (ABUS) is indicated as an adjunct to mammography for breast cancer screening in asymptomatic women with high-density breast tissue. ABUS provides time-efficient evaluation of the 3-dimensional recordings within 3 to 6 minutes. The role and advantages of ABUS in everyday clinical practice, especially in routine examination during neoadjuvant chemotherapy (NACT), is not clear. The aim of this monocentric, noninterventional retrospective study is to evaluate the use of ABUS in patients who are under NACT treatment for response control. Methods: Regular sonographic response check with handheld ultrasound (HHUS) examination and with ABUS were conducted in 83 women who underwent NACT. The response controls were conducted every 3 to 6 weeks during NACT. The handheld sonography was performed with GE Voluson S8. Handheld sonographic measurements and ABUS measurements were compared with the final pathologic tumor size. Results: There was no statistical difference between the measurements with HHUS examination or ABUS compared with final pathologic tumor size (P =.47). The average difference from ABUS measured tumor size to final pathologic tumor size was 9.8 mm. The average difference from handheld measured tumor size to final pathologic tumor size was 9/3 mm. Both the specificity of ABUS and HHUS examination in predicting pathologic complete remission was 100%. Conclusion: ABUS seems to be a suitable method to conduct response control in neoadjuvant breast cancer treatment. ABUS may facilitate preoperative planning and offers remarkable time saving for physicians compared with HHUS examination and thus should be considered for clinical practice (C) 2021 Elsevier Inc. All rights reserved.
Metadaten zuletzt geändert: 29 Feb 2024 12:47