Extracorporeal Circulatory Systems as a Bridge to Lung Transplantation at Remote Transplant Centers

Haneya, Assad ; Philipp, Alois ; Mueller, Thomas ; Lubnow, Matthias ; Pfeifer, Michael ; Zink, Wolfgang ; Hilker, Michael ; Schmid, Christof ; Hirt, Stephan



Zusammenfassung

Background. Worsening of lung function in patients awaiting lung transplantation can lead to ventilation-refractory hypoxemia or hypercapnia and respiratory acidosis. This report describes the successful use of different extracorporeal circulatory systems as a bridge to transplantation at remote centers. Methods. Between January 2003 and December 2009, we had 10 requests for implantation of ...