Minimal Extracorporeal Circulation: An Alternative for On-Pump and Off-Pump Coronary Revascularization

Puehler, Thomas ; Haneya, Assad ; Philipp, Alois ; Wiebe, Karsten ; Keyser, Andreas ; Rupprecht, Leopold ; Hirt, Stephan ; Kobuch, Reinhard ; Diez, Claudius ; Hilker, Michael ; Schmid, Christof



Zusammenfassung

Background. Coronary artery bypass surgery employing minimal extracorporeal circulation (MECC) was compared with standard extracorporeal circulation (ECC) and off-pump coronary artery bypass graft surgery (OPCABG) with regard to the perioperative course. Methods. From January 2004 to December 2007, 1,674 patients (n = 558 MECC, n = 558 ECC, n = 558 OPCABG) who underwent coronary bypass surgery ...