Electrolyte Conductivity of NaSCN in Propan-1-ol and Propan-2-ol Solutions at Temperatures from 228 K to 298 K

Tsurko, Elena N. ; Neueder, Roland ; Barthel, Josef



Zusammenfassung

Conductivity measurements of sodium thiocyanate solutions in propan-1-ol and propan-2-ol in the concentration range from (0.0001 to 0.004) mol.kg(-1) from 228.15 K to 298.15 K have been performed with high precision. Data analysis has been performed on the basis of the chemical model (CM) of electrolyte solutions including short-range interactions.